Port MODELACCESS ๐Ÿ›ˆยถ

Stimulationยถ

Restrictions:

  • Stimulus input signals are not supported.

  • Trace files being referenced by a DataFileSegment in an STI file are not converted automatically by ecu.test.

Supported execution modesยถ

See also: Specifics of time modes

Preferred time source/mode: Real-time

Real-time:

To use real-time mode, the Test configuration in the Execution tab must be configured as the source โ€˜real timeโ€™.

Info

The following modes are not supported: Stepwise simulation time, Continuous simulation time

Name

Available if

Default value

Valid values

Type

Description

Channel entrance level

Controller

uri

Path of entry level for query the VeriStand channels

DeployProjectยถ

Deploys the system definition file associated with an NI VeriStand project to the target.

GetSystemStateยถ

Returns the current system state.

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

string

Current system state

ReadVariableยถ

Reads a scalar from a model variable

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

VariablePath

uri

Path to a model variable

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int

Value of a model variable

UndeployProjectยถ

Undeploys the system definition file associated with an NI VeriStand project from the target. Undeploying the system definition file stops execution on the target.

WriteVariableยถ

Writes a scalar into a model variable

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

Value

string

Value to write into a model variable

VariablePath

uri