Port MODELACCESS - DEFAULT πŸ›ˆΒΆ

Model access

StimulationΒΆ

This port has no stimulus capabilities.

Supported execution modesΒΆ

See also: Specifics of time modes

Preferred time source/mode: Continuous simulation time

Real-time:

To use real-time mode, the Test configuration in the Execution tab must be configured as the source β€˜real time’.

Continuous simulation time:

To use the continuous simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to β€˜continuous’.

Info

The following modes are not supported: Stepwise simulation time

Name

Available if

Default value

Valid values

Type

Description

Time resolution [ms]

10

int

Resolution of the simulation time in milliseconds (simulation step size).

Maximum ratio of model time to system time

1.0

float

If the model time in the SIL Kit is significantly faster than the real time, the processing speed of ecu.test may not be sufficient to correctly check or comply with time conditions. If the ratio set here is exceeded, ecu.test delays the simulation accordingly.

GetSimulationTimeΒΆ

Determines the current simulation time in the Vector SIL kit if the model port was selected as time source in the TCF

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

float

Simulation time in seconds