CheckTriggerRange

ID: Check/CheckTriggerRange


This trace step template is used to evaluate the duration of each trigger range and the count of all trigger ranges within a trigger block. It is intended for use within a trigger block.

Note: Not all parameters may be None at the same time.

Signals

Parameters

MinDurationPerTriggerRange

Minimum duration of a single trigger range. If None, this is not evaluated.

  • Direction: IN

MaxDurationPerTriggerRange

Maximum duration of a single trigger range. If None, this is not evaluated.

  • Direction: IN

MinNumberTriggeredRanges

Minimum number of triggered ranges. If None, this is not evaluated.

  • Direction: IN

MaxNumberTriggeredRanges

Maximum number of triggered ranges. If None, this is not evaluated.

  • Direction: IN