Optional setup

Add to homescreen

ecu.test drive can be added to the homescreen. From the homescreen, the app always starts in full-screen mode and without browser elements.

The web page can be added to the homescreen using the browser menu (Chrome / Android) or the share menu (Safari / iOS).

Choose voice for speech output

By default, the speech output in ecu.test drive uses the language that is currently set in ecu.test. To read out test steps that were composed in another language, a different speaker can be selected in ecu.test drive. Open the settings and select the field Speech language. There you can pick the code of your preferred language, for example ‘de-DE’ for German or ‘es-ES’ for Spanish. Which languages are available depends on the browser in use.

Acoustic signals

Calculation steps and Multi-Check test steps with activated time options provide the possibility to indicate undershooting, overshooting, and reaching the desired value range using acoustic signals. For this purpose, the field Acoustic signals in settings must be activated. During test case execution, the option can also be activated or deactivated using the loudspeaker symbol in the upper-left corner of the screen.

The acoustic signals are played as follows:

  • Calculation with time options

    • Falling below the value range: low tone in 1s interval

    • Exceeding the value range: high tone in 0.7s interval

    • Within the value range: continuous tone

  • Multi-Check with time option “fulfilled for all test steps”

    • At least one child test step outside the value range: tone in interval

    • All child test steps within the value range: continuous tone

  • Multi-Check with time option “at least one test step”

    • All child test steps outside the value range: tone in interval

    • At least one child test step within the value range: continuous tone