ETAS: BOAΒΆ
Legacy/internal identifier: ETAS-BOA-HW
Vendor information
Vendor |
Web page |
Product name |
Version |
|---|---|---|---|
ETAS GmbH |
ECU and Bus Interfaces - Integration Package |
2.23 |
Categories
MDL π |
APL π |
BAN π |
BMA π |
SVC π |
DGN π |
FIU π |
EES π |
FCT π |
DBG π |
IMG π |
AUDIO π |
ENVSIM π |
ENVCOM π |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
β |
β |
Signal recordings π
File format |
Comment |
|---|---|
*.asc |
|
*.mf4 |
BUSACCESS - CAN(-FD) ports support MDF4 bus logging only. XCP ports support signal-based MDF4 recording. |
*.pcapng |
BUSACCESS - CAN(-FD) ports will use linktype=227. The resulting files cannot be processed by trace analysis. |
Platform
Operating system |
Support |
|---|---|
Windows |
β |
Linux |
PortsΒΆ
SpecificsΒΆ
This interface allows, by means of hardware, direct CAN bus access. It supports the test steps read signal, read/write signal group as well as monitor and supports signal recording, Raw diagnostics with KWP2000 over ISO-TP, the Mini residual bus simulation and Additional functions of the close-to-hardware bus connections.
Info
The APPLICATION ports can only be used with the Add-on ecu.test calibration
Supported drivers
To use the driver in ecu.test, it is necessary that the dll directory (e.g.
C:/Program Files/ETAS/BOA_V2/Bin/x64/Dll/Framework) is added to the PATH
variable.
Additionally the correct driver for the used hardware has to be installed. Installation is usually done via the Hardware Service Pack.
Info
Not all ETAS hardware is supported by the 64 bit version of BOA.
Tested hardware:
Vector VN8970
Vector VN1610
ETAS ES582.1
ETAS ES584.1
Properties πΒΆ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Hardware |
[β<online query>β, β<no toollib start>β] |
string |
Choose the hardware which should be used |
||
Debug |
β |
bool |
|||
Timeout for tool call β²in sec.β³ |
β600β |
string |