NI: VeriStandΒΆ
Legacy/internal identifier: VERISTAND
Vendor information
Vendor |
Web page |
Product name |
Version |
|---|---|---|---|
National Instruments |
VeriStand |
From 2021 |
Categories
MDL π |
APL π |
BAN π |
BMA π |
SVC π |
DGN π |
FIU π |
EES π |
FCT π |
DBG π |
IMG π |
AUDIO π |
ENVSIM π |
ENVCOM π |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
β |
β |
Platform
Operating system |
Support |
|---|---|
Windows |
β |
Linux |
PortsΒΆ
SpecificsΒΆ
To write a model parameter, you can use the variables in the tree node β<Model Parameters>β. These variables are also listed in VeriStand in the βModel Parameter Managerβ. After writing a variable, it can take a view milliseconds until the new value can be read from the signal. Parameters can not be recorded.
Aliases can be accessed via the tree node β<Aliases>β. For aliases that point to a model parameter, direct writing is not supported. Please use the node β<Model Parameters>β to manipulate such values.
With the node β<Channel Fault Manager>β a signal can be forced to a specific value. By writing to a quantity listed under this node, a fault is applied to the coresponding signal. Subsequent Read test steps to that signal will then always return the specified value. Executing a Reset step on the faulted channel will remove the fault. The signal will then return its true value again when read. For more information on the usage of the Channel Fault Manager please refer to the VeriStand help.
Properties πΒΆ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Version |
[ONLINE] |
string |
Version of VersiStand |
||
Project file |
uri |
Project file (*.nivsproj) as an absolute path or relative to the base path of the tool host. |
|||
User name |
βAdministratorβ |
string |
User login |
||
Password |
string |
Password for user |
|||
Deploy at start |
β |
bool |
Load system definitions at start to the real-time computer. |
||
Open workspace after connect |
β |
bool |
If this option is set to True, the workspace will be opened automatically after connecting with VeriStand. |
||
Open project explorer after connecting |
β |
bool |
If this option is enabled, the Project Explorer is displayed, otherwise not. |
||
Access timeout in ms |
300000 |
int |
Timeout for waiting of a VeriStand API response. |
||
Sample rate for recording |
1000 |
float |
Record with the specified frequency in Hz. If the value is greater than the modelβs sample rate, all samples will be recorded. |
||
Undeploy project on disconnect |
β |
bool |
Enabling this option causes the VeriStand project to be undeployed when ecu.test disconnects. |
||
Close project on disconnect |
β |
bool |
Enabling this option causes the project in VeriStand to be closed on disconnect from ecu.test. |
||
Close tool on disconnect |
β |
bool |
Enabling this option causes VeriStand to be closed on disconnect from ecu.test. |
||
Sampling rate β²1/secondβ³ for playing stimuli |
1000 |
int |
When stimulated, the STI file is translated into a list of timestamps. This setting determines how many entries should be created per second. |
||
Timeout for tool call β²in sec.β³ |
β600β |
string |
Timeout after which a tool call is aborted. |