Skip to content
logo
ecu.test 2025.3 Help
Port APPLICATION - Standard 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: Morphée
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
        • Ports
          • Port APPLICATION - Standard 🛈
            • Stimulation
            • Properties 🛈
            • Jobs 🛈
              • DownloadWorkbase
              • GetAquisitionRates
              • IsDeviceRunning
              • StartDevice
              • StopDevice
          • Port BUSACCESS - Standard 🛈
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Properties 🛈
    • Jobs 🛈
      • DownloadWorkbase
      • GetAquisitionRates
      • IsDeviceRunning
      • StartDevice
      • StopDevice

    Port APPLICATION - Standard 🛈¶

    Stimulation¶

    This port has no stimulus capabilities.

    Properties 🛈¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Device name

    ‘CCPsim’

    string

    Name of access interface

    Device channel

    1

    int

    Name of access interface

    Devices

    CCP

    [CCP, XCP]

    string

    Driver of access interface

    Network name

    Devices: ‘Ethernet’

    string

    Name of ethernet network (for network based access mode). Leave empty for channel based access mode.

    Check access

    ☑

    bool

    Check device access after tool startup.

    A2L file

    uri

    A2L file used by the port

    Hex file

    uri

    Hex file used by the port

    Mirror cache

    Ignore

    [Ignore, Disable, Enable]

    uri

    Enable or diable the mirror cache after initialisation of the device. Only has an effect on devices that are created by ecu.test.

    Automatic recording

    ☐

    bool

    If this option is active, all signals used in the test case are automatically registered for recording.

    Default acquisition rate

    ‘Tool-Default’

    string

    Declaration of measurement acquisition rate used as alternative in case no acquisition rate is set in the test step (’*’ and ‘?’ can be used as wildcard). “Tool-Default” activates the use of the standard acquisition rate of the tool

    Procrastination for validation

    -1

    int

    Defines the procrastination used for validating a written calibration value. If set to “-1” no validation will be performed.

    Validation tolerance for calibration

    3

    float

    Defines the tolerance used for validating a written calibration value. The value must be given in percent.

    Force upload of calibration values

    ☐

    bool

    From CANape 12 SP8: Forces uploading calibration values. This is necessary when a calibration value is also written by the control unit software.

    Do not transfer A2L and HEX file to CANape

    ☐

    bool

    This setting allows to skip the time for copying and reading the A2L and HEX files into CANape, if a CANape project which already includes the correct file is used.

    Jobs 🛈¶

    DownloadWorkbase¶

    Download WP/RP from data set to control unit

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    force

    False

    [False, True]

    bool

    GetAquisitionRates¶

    Provides a list of all acquisition rates

    IsDeviceRunning¶

    Returns if the ECU is online.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    [False, True]

    bool

    StartDevice¶

    Establishes the connection from CANape to the ECU

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    download

    False

    [False, True]

    bool

    Activates the automatic download during “GoOnline”.

    timeout

    2000

    float

    Timeout for the start in ms.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    [False, True]

    bool

    StopDevice¶

    Disconnects the ECU from CANape

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    timeout

    2000

    float

    Timeout for the stop in ms.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    [False, True]

    bool

    2025-12-05
    Previous
    Vector: CANape
    Next
    Port BUSACCESS - Standard 🛈
    © Copyright 2025, tracetronic GmbH.