Skip to content
logo
ecu.test 2025.3 Help
Port APPLICATION - Standard 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
        • Ports
          • Port APPLICATION - Standard 🛈
            • Stimulation
            • Properties 🛈
            • Jobs 🛈
              • AutoDownloadWorkbase
              • CheckConnection
              • ChecksumCodePage
              • ChecksumDataPages
              • CopyReferencePageToWorkingPage
              • CreateDifferencesReport
              • DcmToHex
              • DownloadDifferences
              • DownloadWorkbase
              • FlashHexFileWithControlFlow
              • GetAquisitionRates
              • GetDeviceType
              • GetDifferencesCounter
              • GetEPKfromASAP2
              • GetEPKfromDS
              • GetEPKfromECU
              • GetHwcState
              • GetLabels
              • GetMemPageState
              • GetSupportedFlashPortNames
              • HexToHex
              • IsCalibrationPossible
              • IsTargetEcuOff
              • ReadAllCalibrationsFromFile
              • ReadCalibration
              • ReadFromDataPage
              • ReadMeasurement
              • ResetToReferencePage
              • ResumeCyclicCommands
              • SetAsyncBuffersToInvalid
              • SetStoreBit
              • SuppressCyclicCommands
              • SwitchToReferencePage
              • SwitchToWorkingPage
              • UploadWorkbase
              • WriteCalibration
              • WriteToDataPage
              • WriteWorkpageToFile
          • Port BUSACCESS 🛈
          • Port APPLICATION - Simulation 🛈
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: MorphĂ©e
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Properties 🛈
    • Jobs 🛈
      • AutoDownloadWorkbase
      • CheckConnection
      • ChecksumCodePage
      • ChecksumDataPages
      • CopyReferencePageToWorkingPage
      • CreateDifferencesReport
      • DcmToHex
      • DownloadDifferences
      • DownloadWorkbase
      • FlashHexFileWithControlFlow
      • GetAquisitionRates
      • GetDeviceType
      • GetDifferencesCounter
      • GetEPKfromASAP2
      • GetEPKfromDS
      • GetEPKfromECU
      • GetHwcState
      • GetLabels
      • GetMemPageState
      • GetSupportedFlashPortNames
      • HexToHex
      • IsCalibrationPossible
      • IsTargetEcuOff
      • ReadAllCalibrationsFromFile
      • ReadCalibration
      • ReadFromDataPage
      • ReadMeasurement
      • ResetToReferencePage
      • ResumeCyclicCommands
      • SetAsyncBuffersToInvalid
      • SetStoreBit
      • SuppressCyclicCommands
      • SwitchToReferencePage
      • SwitchToWorkingPage
      • UploadWorkbase
      • WriteCalibration
      • WriteToDataPage
      • WriteWorkpageToFile

    Port APPLICATION - Standard đŸ›ˆÂ¶

    Stimulation¶

    This port has no stimulus capabilities.

    Properties đŸ›ˆÂ¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Device name

    ‘CCP:1’

    string

    Name of access interface

    Device type

    ‘undefined’

    string

    <System type>.<Device type> (e.g. “TS-Testsystem.ETK-Testdevice”). Dots in the type name must be escaped with a backslash.

    “undefined” if you want to use an existing device with the specified name.

    A2L file

    string

    A2L file used by the port. If a similarly named *.al2.cod fileexists at the same location, it is transferred to INCA wheneverthe A2L file is transferred.

    Hex file

    string

    Hex file used by the port

    Automatic recording

    ☑

    bool

    If this is active, all measurement values in the test case are registered for recording.

    Default acquisition rate

    ‘Tool-Default’

    string

    Declaration of measurement acquisition rate used as alternative in case no acquisition rate is set in the test step (’*’ and ‘?’ can be used as wildcard). “Tool-Default” activates the use of the standard acquisition rate of the tool

    LAB file

    string

    LAB file to be added to the INCA recorder. If the LAB file already exists, it will be overwritten.

    Refresh page

    ‘Auto (Ignition Off/On)’

    [‘Auto (Ignition Off/On)’, ‘Full download’, ‘Download differences’, ‘Copy RP to WP’, ‘No action’]

    string

    Determines the behaviour of page updating.

    Write calibration values check

    ☑

    bool

    Return values of the INCA-API are evaluated to check if writing was successfully.

    If this option is activated an error is raised if the check failed.

    Deactivate this option if there are e.g. problems with fix axis maps

    Load ECU-Project

    0

    [0, 1, 2]


    Display values:

    • 0: Use existing dataset

    • 1: Create new dataset

    • 2: Replace ASAP2 project

    string

    Specifies how to handle existing ASAP2 projects. This option is relevant if the HEX file or A2L file content changes but not their file names.

    Do not transfer A2L and HEX file to INCA

    Load ECU-Project: ‘0’

    ☐

    bool

    If selected A2L and HEX files are not transfered to INCA. Requires that project and data set exist in the INCA database under given path and file name (without extension).

    Set hard bounds

    ☑

    bool

    Permanently use hard bounds instead of weak bounds

    Transport layer instance

    string

    Name of the transport layer instance (optional).

    Extra hardware options

    ‘{}’

    string

    Expert option.

    Dictionary with additional hardware options, e.g. {‘MeasureFailureBehavior’: ‘2’, ‘PageSwitch’: ‘true’, ‘ConnectionInterruptBehavior’: ‘autoReinitializeAndDownload’}.

    Requires INCA 7.2.6 or later.

    Option ‘Transport layer instance’ has precedence over specifying ‘TransportLayer’ here.

    See also INCA API documentation for SetOption.

    Restore behaviour

    ‘Value at test start’

    [‘Value at test start’, ‘Value from reference page’]

    string

    Determines which value is used by the test step ‘Restore’ and by automatic restore of test quantities.

    Jobs đŸ›ˆÂ¶

    AutoDownloadWorkbase¶

    Automatic Download WP/RP from data set to control unit

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    force

    ☐

    bool

    Force download (True/False)

    CheckConnection¶

    Get connection state

    ChecksumCodePage¶

    Create checksum over code page

    ChecksumDataPages¶

    Create checksum over WP and RP

    CopyReferencePageToWorkingPage¶

    Copy RP to WP

    CreateDifferencesReport¶

    Creates a report regarding the differences between working page and reference page in the given format at the given local path.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    ignoreCdmErrors

    ☐

    bool

    Ignore non-critical CDM toolbox errors and create report file anyway.

    reportFile

    string

    Local path of the resulting report file.

    reportFormat

    ‘HTML’

    [‘HTML’, ‘ASCII’]

    string

    Format in which to generate the report file. Can be “HTML” or “ASCII”.

    DcmToHex¶

    Creates a new DataSet for the device from the DCM file(s) and saves it to the Hex file. Caution! The files must not be in the ToolLibTemp directory.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    dcmFile

    object

    DCM file(s) to be processed

    hexFile

    string

    Hex file (output)

    ignoreCdmErrors

    ☐

    bool

    Ignore failures of CDM-Toolbox and fetch Hex file.

    DownloadDifferences¶

    Download difference

    DownloadWorkbase¶

    Download WP/RP

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    force

    ☐

    bool

    Force download (True/False)

    FlashHexFileWithControlFlow¶

    Flashes the ECU when the measurement is stopped

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    ControlFlow

    string

    ControlFlow from TGTSVR.log without device and .hex file

    CopyFile

    ☐

    bool

    If “True”, copies the local file to the tool host

    FlashFile

    uri

    Optional: file name and path of the flash file

    FlashPort

    [‘’, ‘<online query>’]

    string

    Optional: Alternative flash port

    GetAquisitionRates¶

    Provides a list of all acquisition rates

    GetDeviceType¶

    Returns the device type

    GetDifferencesCounter¶

    Returns the count of variables changed in working page.

    GetEPKfromASAP2¶

    Returns the EPROM ID (EPK) from assigned ASAP2. Returns the EKP string of a2l.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    EPK

    string

    String with ID

    GetEPKfromDS¶

    Returns the EPROM ID (EPK) from assigned dataset. Returns the EKP string of dataset.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    EPK

    string

    String with ID

    GetEPKfromECU¶

    Returns the EPROM ID (EPK) from ECU. Returns the EKP string of ECU.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    EPK

    string

    String with ID

    GetHwcState¶

    Queries a state value from the ‘HWC’ module

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    stateName

    [‘BaudRate’, ‘GetDifferencesCounter’, ‘CheckOfState’]

    string

    Name of the state value to query

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    state value as string

    GetLabels¶

    Provides a list of all values

    GetMemPageState¶

    Queries a state value from the ‘MEMORYPAGE’ module

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    stateName

    [‘EPKfromDS’, ‘EPKfromASAP2’, ‘EPKfromECU’, ‘CS_RP_Dataset’, ‘CS_RP_ECU’, ‘CS_WP_Dataset’, ‘CS_WP_ECU’]

    string

    Name of the state value to query

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    state value as string

    GetSupportedFlashPortNames¶

    Returns the names of supported FlashPorts

    HexToHex¶

    Creates a new DataSet based on the HEX file from the test configuration, with data from the specified HEX file. The files must NOT lie in the ToolLibTemp directory. Caution! This Job does not work with INCA versions older than 7.2.4!

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    ignoreCdmErrors

    ☐

    bool

    Ignore failures of CDM-Toolbox and fetch Hex file.

    InputHexFile

    string

    HEX file with compatible data set

    OutputHexFile

    string

    Hex file (output)

    IsCalibrationPossible¶

    Checks whether the calibration access is currently possible

    IsTargetEcuOff¶

    Returns whether the device is switched off (since INCA 7.2.11)

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Off

    ☐

    bool

    True if switched off, False otherwise

    ReadAllCalibrationsFromFile¶

    Applies the calibration values from the specified file to the device. Prerequisites: INCA 7.2.6 or newer, measurement stopped, working page activated.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    dcmFile

    object

    DCM file (or other supported format), from which to read the calibration values

    ReadCalibration¶

    Reads a calibration value

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Name

    string

    Name of quantity to be read

    TypeInfo

    ‘SCALAR’

    [‘SCALAR’, ‘VECTOR’, ‘MATRIX’, ‘CURVE’, ‘MAP’]

    string

    Variable type of quantity

    ReadFromDataPage¶

    Reads the data of a memory area.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Length

    int

    Length of the area

    StartAddress

    int

    Start address of memory area

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    Read data as tuple of signed integer values

    ReadMeasurement¶

    Adds label to experiment and reads it

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Name

    string

    Name of quantity to be read

    Raster

    string

    Name of acquisition rate

    SuppressErrors

    ☐

    bool

    If set to True, runtime errors will not result in an ERROR in the report, instead ~Not Present~ will be returned.

    ResetToReferencePage¶

    Resets the specified characteristics to the value from the reference page

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Labels

    object

    List of labels to be reset

    ResumeCyclicCommands¶

    Resume the sending of cyclic commands to XCP slave

    SetAsyncBuffersToInvalid¶

    Invalidate asynchronous measurement data buffers for the device (since INCA 7.2.11)

    SetStoreBit¶

    Set store bit

    SuppressCyclicCommands¶

    Suppress the sending of cyclic commands to XCP slave

    SwitchToReferencePage¶

    Change to reference page

    SwitchToWorkingPage¶

    Change to working page

    UploadWorkbase¶

    Upload the working and reference page

    WriteCalibration¶

    Writes a calibration value

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Data

    string

    data to be written

    Name

    string

    Name of value to be written

    TypeInfo

    ‘SCALAR’

    [‘SCALAR’, ‘VECTOR’, ‘MATRIX’, ‘CURVE’, ‘MAP’]

    string

    Variable type of quantity

    WriteToDataPage¶

    Write data in the specified memory range.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Length

    int

    Number of bytes to write

    StartAddress

    int

    Start address for the data to write

    Values

    ByteStream

    The data to write as ByteStream

    WriteWorkpageToFile¶

    Creates a Hex file from the current working page. Warning! The target file must not be stored in the ToollibTemp directory.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    hexFile

    string

    Hex-File to be processed

    2025-12-05
    Previous
    ETAS: INCA
    Next
    Port BUSACCESS 🛈
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH