Skip to content
logo
ecu.test 2025.3 Help
Port DIAGNOSTICS_JOBS - DEFAULT 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: Morphée
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
        • Ports
          • Port DIAGNOSTICS_JOBS - DEFAULT 🛈
            • Stimulation
            • Properties 🛈
            • Jobs 🛈
              • ActuatorDiagnosticsInit
              • ActuatorDiagnosticsStart
              • ActuatorDiagnosticsStop
              • BasicSetting2Init
              • BasicSettingCheck
              • BasicSettingStart
              • BasicSettingStop
              • CheckFlashProgramming
              • CheckFlashProgrammingWithFlashContainer
              • CloseConnection
              • ConnectToEcu
              • ConnectToEcuAndOpenConnection
              • DataSetDownload
              • FlashProgramming
              • GetFlashSessions
              • GetShortNamesOfAccessModes
              • GetShortNamesOfActuators
              • GetShortNamesOfAdaptationChannels
              • GetShortNamesOfAdaptationValues
              • GetShortNamesOfBasicSettings
              • GetShortNamesOfCodingValues
              • GetShortNamesOfDiagnosticSessions
              • GetShortNamesOfIdentificationDatas
              • GetShortNamesOfMeasurementGroups
              • GetShortNamesOfMeasurements
              • GetShortNamesOfMeasurementsForBasicSettings
              • GetShortNamesOfStartParametersForActuator
              • GetShortNamesOfStartParametersForBasicSettings
              • GetShortNamesOfSubSystems
              • LockConnection
              • ReadAdaptation
              • ReadCoding
              • ReadDevEventMemory
              • ReadEEPROMSerial
              • ReadEventMemory
              • ReadEventMemoryWithMask
              • ReadGatewayComponentList
              • ReadIdentification
              • ReadIdentificationData
              • ReadMeasurement
              • ResetEventMemory
              • SecurityAccess
              • SecurityAccessSFDCheckStatus
              • SecurityAccessSFDEcuLock
              • SecurityAccessSFDOffline
              • SecurityAccessSFDOnline
              • SecurityAccessSFDReset
              • SendRawService
              • SwitchSession
              • UnlockConnection
              • WriteAdaptation
              • WriteByteCoding
              • WriteTextCoding
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Properties 🛈
    • Jobs 🛈
      • ActuatorDiagnosticsInit
      • ActuatorDiagnosticsStart
      • ActuatorDiagnosticsStop
      • BasicSetting2Init
      • BasicSettingCheck
      • BasicSettingStart
      • BasicSettingStop
      • CheckFlashProgramming
      • CheckFlashProgrammingWithFlashContainer
      • CloseConnection
      • ConnectToEcu
      • ConnectToEcuAndOpenConnection
      • DataSetDownload
      • FlashProgramming
      • GetFlashSessions
      • GetShortNamesOfAccessModes
      • GetShortNamesOfActuators
      • GetShortNamesOfAdaptationChannels
      • GetShortNamesOfAdaptationValues
      • GetShortNamesOfBasicSettings
      • GetShortNamesOfCodingValues
      • GetShortNamesOfDiagnosticSessions
      • GetShortNamesOfIdentificationDatas
      • GetShortNamesOfMeasurementGroups
      • GetShortNamesOfMeasurements
      • GetShortNamesOfMeasurementsForBasicSettings
      • GetShortNamesOfStartParametersForActuator
      • GetShortNamesOfStartParametersForBasicSettings
      • GetShortNamesOfSubSystems
      • LockConnection
      • ReadAdaptation
      • ReadCoding
      • ReadDevEventMemory
      • ReadEEPROMSerial
      • ReadEventMemory
      • ReadEventMemoryWithMask
      • ReadGatewayComponentList
      • ReadIdentification
      • ReadIdentificationData
      • ReadMeasurement
      • ResetEventMemory
      • SecurityAccess
      • SecurityAccessSFDCheckStatus
      • SecurityAccessSFDEcuLock
      • SecurityAccessSFDOffline
      • SecurityAccessSFDOnline
      • SecurityAccessSFDReset
      • SendRawService
      • SwitchSession
      • UnlockConnection
      • WriteAdaptation
      • WriteByteCoding
      • WriteTextCoding

    Port DIAGNOSTICS_JOBS - DEFAULT 🛈¶

    Stimulation¶

    This port has no stimulus capabilities.

    Properties 🛈¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Automatically connect to ECU

    ☑

    bool

    Defines whether the connection to the ECU is established automatically or if it is established manually by using a port job

    ECU address

    0

    int

    Address of the control unit

    Jobs 🛈¶

    ActuatorDiagnosticsInit¶

    Initializes the actuator diagnosis with the specified actuators. The initialization must be called to start the actuator diagnosis.

    For UDS control units settings and measurement values can be configured, which will be read for every basic setting by a check operation.

    For KWP control units the settings are limited to one object and the measurement values will be ignored.

    Ensures that the following operation will run over the same diagnostic connection.

    ODIS requires that the ECU connection has been established with ConnectToEcuAndOpenConnection.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    actuators

    []

    object

    The actuators to initialize as python dict.

    structure:

    {shortName1: {

    parameters: {param1:value1, param2:value2, …},
    measurements: [mParam1,mParam2]},

    shortName2: …}

    measurements

    object

    The measurements values in a list. Can be None.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ActuatorDiagnosticsStart¶

    Starts the actuator diagnosis for the specified actuators (UDS control units) or the actuator specified in actuatorDiagnosticsInit (KWP control units).

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    actuators

    object

    List of the actuator shortNames to start.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    The status of the start operation.

    ActuatorDiagnosticsStop¶

    Stops the actuator diagnosis for the specified actuators (UDS control units) or the actuator specified in actuatorDiagnosticsInit (KWP control units).

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    actuators

    object

    List of the actuator shortNames to start.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    The status of the stop operation.

    BasicSetting2Init¶

    Initializes the basic setting diagnosis with the specified settings. The initialization must be called to start the basic setting diagnosis.

    For UDS control units a list of settings and a list of measurement values can be configured optionally, which will be read for every basic setting by a check operation. The specified measurements can be configured for different control units.

    For KWP control units the list of settings is limited to one object and the list of measurement values will be ignored.

    Ensures that the following operation will run over the same diagnostic connection. After calling this function switching to another ECU is not allowed. For UDS control Units calling basicSettingAbort releases this state.

    ODIS requires that the ECU connection has been established with ConnectToEcuAndOpenConnection.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    basicSettings

    {}

    object

    The basic setting to be initialized as a Python dict.

    structure:

    {shortName1: {

    parameters: {param1:value1, param2:value2, …},
    measurements: [mParam1,mParam2]},

    shortName2: …}

    measurements

    None

    object

    The measurements values in a list. Can be None.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    BasicSettingCheck¶

    Starts the basic setting check for the specified settings (UDS control units) or the settings configured in “basicSetting2Init” (KWP control units).

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    basicSettings

    []

    object

    List with shortnames of the basic settings to be checked.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    The status of the start operation.

    BasicSettingStart¶

    Starts the basic setting diagnostics for the specified settings. (UDS control units) or the settings configured in “basicSetting2Init” (KWP control units).

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    basicSettings

    []

    object

    List with shortnames of the basic settings to be started.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    The status of the start operation.

    BasicSettingStop¶

    Stops the basic setting diagnosis for the specified settings. (UDS control units) or the settings configured in “basicSetting2Init” (KWP control units).

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    basicSettings

    []

    object

    List with shortnames of the basic settings to be started.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    The status of the stop operation.

    CheckFlashProgramming¶

    Checks if the current control unit is in principle flashable.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    [False, True]

    bool

    Checks if the current control unit is in principle flashable. If the information is not available the methods returns True.

    CheckFlashProgrammingWithFlashContainer¶

    Checks if the current control unit is flashable with the containerFileName content.

    UDS: Check over expected idents (contains checks of part number and software version)

    KWP: Check of part number and software version

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    containerFileName

    string

    Name of the container file with full path.

    sessionName

    ‘None’

    string

    The session name to use for the update programming. The parameter can be ‘None’.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    [False, True]

    bool

    True if the current control unit is flashable with the containerFileName content.

    CloseConnection¶

    Closes the connection to the current control unit and switches to CLOSE_CONNECTION_BEHAVIOUR.

    In CLOSE_CONNECTION_BEHAVIOUR the connection to a control unit is closed after every call of a diagnostic operation.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ConnectToEcu¶

    Connects to the control unit with the defined address.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ConnectToEcuAndOpenConnection¶

    Opens the diagnostic connection to the control unit specified by the address and switches to STAY_CONNECTED_BEHAVIOUR.

    Existing connections to other control units will be closed. In STAY_CONNECTED_BEHAVIOUR the connection to a control unit stays opened after every call of a diagnostic operation. To change this behavior call closeConnection. The behavior also changes calling connectToEcu and setVehicleProject.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    DataSetDownload¶

    Writing of a data set with XML content into the current control unit.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    xmlFilePath

    string

    Absolute path to the xml or zip file including file name and suffix.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    General response.

    DiagException - If an error occurs while processing the request.

    FlashProgramming¶

    Flashing with an update container.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    checkSessionWithEcu

    None

    [False, True]

    bool

    Switch if check is activated for UDS on expected idents and for KWP on part number and software version.

    Maybe None, than default ‘True’ is used.

    containerFileName

    string

    Name of the container file with full path.

    sessionName

    ‘None’

    string

    The session name to use for the update programming. The parameter can be ‘None’.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    ByteStream

    GetFlashSessions¶

    Returns the names of all flash sessions contained in the specified flash container.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    checkSessionWithEcu

    None

    [False, True]

    bool

    Switch if check is activated for UDS on expected idents and for KWP on part number and software version.

    Maybe None, than default True is used.

    containerFileName

    string

    Name of the container file with full path.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    GetShortNamesOfAccessModes¶

    Returns the ODX-ShortNames of all available access modes for UDS control units. The function throws an exception for KWP control units.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    GetShortNamesOfActuators¶

    Returns the ODX short names of all available actuators from the currently selected control unit. For a KWP control unit this function throws an exception.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    List of all actuator shortnames.

    GetShortNamesOfAdaptationChannels¶

    Returns the ODX short names of all available adaptation channels for UDS control units. For KWP control unit the function throws an exception.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    GetShortNamesOfAdaptationValues¶

    Returns the ODX short names of all available adaptation values from an adaptation channel. For KWP control units the function throws an exception.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    adaptationChannel

    int

    The adaptation channel from which the adaptation values shall be retrieved.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    GetShortNamesOfBasicSettings¶

    Returns the ODX shortnames of all available basic settings of the selected ECU. For a KWP ECU this function throws an exception.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    List with shortnames of all basic settings.

    GetShortNamesOfCodingValues¶

    Reads the coding names from the active control unit.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    The result short names.

    GetShortNamesOfDiagnosticSessions¶

    Returns the ODX-ShortName list of all available diagnostic sessions for UDS control units. The function throws an exception for KWP control units.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    GetShortNamesOfIdentificationDatas¶

    Returns the ODX short names of all identification values for the specified subsystem. For a KWP control unit this function throws an exception.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    subsystem

    string

    Name of the subsystem for which the values will be returned. If the subsystem name is empty the short names of the master ecu will be returned. - String

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    GetShortNamesOfMeasurementGroups¶

    Returns the list of short names of all available measurement value groups of the chosen ECU. For KWP-ECU this function throws an exception.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    The measurement value groups

    GetShortNamesOfMeasurements¶

    Returns ODX short names of all available measurements of the specified measurement group. For KWP control unit this function throws an exception.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    measurementGroup

    string

    The measurement group in order to get the available ODX short names for this group.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    The ODX short names of all available measurements of the specified measurement group

    GetShortNamesOfMeasurementsForBasicSettings¶

    Returns the ODX shortnames of all measured values for the basic setting. For a KWP controller this function throws an exception.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    List with the shortnames of all measured values of the basic settings.

    GetShortNamesOfStartParametersForActuator¶

    Returns the ODX short names of all available parameters from the specified actuator. For a KWP control unit this function throws an exception.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    actuatorName

    int

    The name of the actuator.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    List of all actuator parameter shortNames.

    GetShortNamesOfStartParametersForBasicSettings¶

    Returns the ODX shortnames of all available parameters of the specified basic setting. For a KWP controller this function throws an exception.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    basicSettingName

    int

    The name of the default setting.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    List with shortnames of all basic settings parameters.

    GetShortNamesOfSubSystems¶

    Returns a list of subsystem names of the active ECU.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    LockConnection¶

    Sets a lock for the specified connection.

    A lock guarantees that the connection stays open while operating on other connections.

    Operation calls to other connections will throw an exception when no other connection can be opened in parallel.

    If no lock is set the connection can be closed anytime, depending on the configured number of parallel connections.

    To set a lock it is necessary to switch into STAY_CONNECTED_BEHAVIOUR for the connection by calling the job ‘ConnectToEcuAndOpenConnection’.

    A lock can be removed calling ‘UnlockConnection’.

    Locks will also be removed when calling one of the following operations: ‘CloseConnection’, ‘SetVehicleProject’.

    Any operation working with multiple control units in parallel such as ‘ReadAllEventMemories’, ‘ReadMeasurements’ or ‘CreateProtocolBZD’ will also remove the lock

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ReadAdaptation¶

    Returns current read values of the specified adaptation channel as a list.

    KWP: List length = 1.

    UDS: List length = n (equals the values from ‘getShortNamesOfAdaptationGroups’).

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    adaptationChannel

    string

    The adaptation channel from which the adaptation values shall be retrieved.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ReadCoding¶

    Reads the coding value from the active control unit.

    For UDS control units the plain text coding values and the byte coding will be read.

    For KWP control units only the byte coding value will be read.

    For both types the slave coding values will be read, every slave coding value will be returned as an entry in the result list.

    If the control unit has no slaves the result list contains only one entry.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    ReadDevEventMemory¶

    Reads the developer event memories from the selected control unit including all environmental conditions. For UDS control units only the event memories with the specified status mask will be read. The mask parameter does not effect KWP control units.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    dtcStatusMask

    0xFF

    int

    Specifies the status of the event memories which will be read. Default: 0xFF

    memorySelections

    []

    object

    The memory selections. If empty, all available memory selections will be used. - List of Strings.

    readSnapshotRecord

    False

    [False, True]

    bool

    Switch to activate the reading of snapshot records. Default: False

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ReadEEPROMSerial¶

    Reads (serially) the specified number of memory bytes from the ECU-EEPROM, starting at the startAddress.

    This method is only supported by KWP1281 ECUs.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    numberOfMemoryCells

    string

    Number of cells to read.

    startAddress

    string

    Start address

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    ByteStream

    ReadEventMemory¶

    Reads the event memories from the selected control unit

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ReadEventMemoryWithMask¶

    Reads the event memories from the selected control unit including all environmental conditions. For UDS control units only the event memories with the specified status mask will be read. The mask parameter does not effect KWP control units. In addition, the reading of the snapshot records can be activated via the parameter readSnapshotRecords.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    dtcStatusMask

    0xFF

    int

    Specifies the status of the event memories which will be read. Default: 0xFF

    readSnapshotRecords

    False

    [False, True]

    bool

    Switch to activate the reading of snapshot records. Default: False

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ReadGatewayComponentList¶

    Reads the gateway component list of the currently selected control unit. If the current control unit has no component list the function throws an exception.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    ReadIdentification¶

    Identification of the control unit

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    ReadIdentificationData¶

    Reads a single identification data from the currently selected master conrol unit and returns it. Single identification data can be read for UDS and KWP2000 Service 22 control units and must be specified by an identifier. For UDS control units one of the shortnames returned by getShortNamesOfIdentificationDatas must be used. For KWP control units also an uds shortname must be used to specify the identification data. The shortname will be mapped to an appropiate record data identifier. For a list of mapped shortnames see the automation parameter mapping file. If a specified identifier is not available or cannot be mapped the function returns a result with an appropiate error message as value.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    identDataIdentifier

    []

    object

    Shortname to specify the data which shall be to read. - String

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    ReadMeasurement¶

    Reads the measurements from the currently selected control unit.

    Reads all values from the specified group or - if specified - a specific measurement from that group.

    For KWP control units the reading of block numbers and positions are supported.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    measurementGroup

    string

    The ODX short name of the measurement group or the KWP block number.

    measurementParam

    ‘None’

    string

    The ODX short name of the measurement or the KWP position number.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    Dict with measurement values.

    ResetEventMemory¶

    Deletes the event memories of the selected control unit

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    SecurityAccess¶

    Executes the security access operation on the control unit using the specified login code and access mode.

    KWP2000 access modes: automatic, level34, level56, coding2

    KWP1281 access mode: automatic

    UDS access modes: Login, System Specific

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    accessMode

    string

    The access mode.

    loginCode

    string

    The login code.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    SecurityAccessSFDCheckStatus¶

    Reads the security access unlock status for the specified control unit (SFD).

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    The SFD unlock status

    SecurityAccessSFDEcuLock¶

    Executes the security access lock operation on the specified control unit (SFD).

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    The result of the SFD lock process

    SecurityAccessSFDOffline¶

    Executes the security access unlock operation on the control unit by using an offline token (SFD) without a connection to the sfd backend. A offline token must be present for the specified ecu, role and duration in the sfd-token directory (see ODIS-Admin).

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    duration

    [‘SHORT’, ‘LONG’, ‘UNLIMITED’]

    string

    The durations for the SFD unlock operation

    role

    [‘EPTI’, ‘BASIC’, ‘EXTENDED’, ‘SUPERUSER’, ‘PRODUCTION’, ‘OTA’]

    string

    The role for the SFD unlock operation

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    The result of the SFD unlock operation

    SecurityAccessSFDOnline¶

    Executes the security access unlock operation on the control unit by using an online token (SFD). The online token is requested from the sfd backend system.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    accessMethod

    [‘PKI’, ‘SoftPSE’, ‘TBT_TOKEN’]

    string

    The online access method for the backend system

    duration

    [‘SHORT’, ‘LONG’, ‘UNLIMITED’]

    string

    The durations for the SFD unlock operation

    role

    [‘EPTI’, ‘BASIC’, ‘EXTENDED’, ‘SUPERUSER’, ‘PRODUCTION’, ‘OTA’]

    string

    The role for the SFD unlock operation

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    The result of the SFD unlock operation

    SecurityAccessSFDReset¶

    Executes the security access reset operation on the control unit by using an online token (SFD). This operation resets the control unit to the initial protection values and is only allowed by the user role ‘SUPERUSER’. The online token is requested from the sfd backend system.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    accessMethod

    [‘PKI’, ‘SoftPSE’, ‘TBT_TOKEN’]

    string

    The online access method for the backend system

    duration

    [‘SHORT’, ‘LONG’, ‘UNLIMITED’]

    string

    The durations for the SFD unlock operation

    role

    [‘EPTI’, ‘BASIC’, ‘EXTENDED’, ‘SUPERUSER’, ‘PRODUCTION’, ‘OTA’]

    string

    The role for the SFD unlock operation

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    The result of the SFD reset operation

    SendRawService¶

    Writes raw hex data.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    requestPdu

    ByteStream

    Raw diagnostic data (PDU) as Bytestream, e.g.: ‘ByteStream(‘20:FF:FF:FF’)

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    SwitchSession¶

    For UDS control units the ODX short name of the diagnostic session is used to identify the session to switch to.

    For KWP control units the following identifier are used:

    00 VAS505x mode

    83 End of line within volkswagen

    84 End of line within control unit producer

    85 Update programming

    86 Developper mode

    89 Standard selfdiagnostics

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    session

    string

    Diagnostic session to switch to.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    UnlockConnection¶

    Removes the lock for the specified connection.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    WriteAdaptation¶

    Writes adaption values for the specified adaptation channel. The adaption channel and the value(s) to be written are to be specified in different ways for UDS and KWP.

    For UDS the adaptation channel is one of the channels returned by getShortNamesOfAdaptationChannels and the available values for the channel can be retrieved by getShortNamesOfAdaptationValues.

    The adaptation values to be written are passed to this function by a key value dictionary. The key specifies the short name of the adaptation value and the value specifies the adaptation value to be written.

    For KWP the adaptation channel is the channel number given as string - i.e. ‘1’ to ‘255’.

    The adaptation value to be written is to be passed as the single entry in the key value dictionary with the adaption channel serving as key.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    adaptationChannel

    string

    The adaptation channel to which the adaptation values shall be written.

    adaptationValues

    object

    The adaptation values which shall be written. Example for a key/value pair: {‘Param_ActiveStartStopFunct’: ‘active’}.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    WriteByteCoding¶

    Writes coding values for the specified (sub)system.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    codingValue

    string

    The coding value to write in String representation. For KWP short coding the value is expected as an integer value. For KWP long coding and UDS binary coding a byte array is expected.

    systemName

    string

    The (sub)system name. KWP subsystems start with prefix subSys followed by the index.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    ByteStream

    WriteTextCoding¶

    Writes the text coding values for the specified system.

    The function is only defined for UDS control units.

    For the system name of the master control unit the constant ‘master’ or the shortname can be used.

    For KWP control units an exception will be thrown.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    codingValues

    object

    The plain text coding values as dictionary with Key/Value pairs.

    Key = ShortNamesOfCodingValue

    Value = Coding Value

    ecuReset

    [False, True]

    bool

    Do a reset after writing?

    systemName

    string

    The (sub)system name. KWP subsystems start with prefix subSys followed by the index.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    2025-12-05