Port APPLICATION - GENERIC πΒΆ
Generic application access
StimulationΒΆ
This port has no stimulus capabilities.
SpecificsΒΆ
With this port type you can read and manipulate application labels that are represented in the model. It assumes that the model variables have the exact same name as the names in the A2L.
Info
Using the APL-Port together with an A2L file only works properly, if the renaming feature in SILVER is not used. The variables names have to be unmodified, otherwise ecu.test is not able to access the correct values.
Properties πΒΆ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
A2L file |
string |
A2L file used by the port |
|||
Model port |
string |
Port ID (e.g. βMDL01β) of the model port via which the model access is to be performed. This property can remain empty if there is exactly one model port. If there is more than one model port, this property must be set. |