Port NULL - IO πΒΆ
TechnicaBTS I/O
StimulationΒΆ
This port has no stimulus capabilities.
Properties πΒΆ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Board IDs |
string |
IDs (last octet of the IP address) of the boards to be used, separated by commas |
Jobs πΒΆ
GetPotiΒΆ
Read Poti
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
channelNo |
12 |
int |
Channel number (per board, counting from 0) |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
poti |
int |
Poti value |
GetVoltageΒΆ
Read voltage
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
channelNo |
int |
Channel number (per board, counting from 0) |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
voltage |
float |
Voltage |
OpenCircuitΒΆ
Set channel to open circuit
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
channelNo |
int |
Channel number (per board, counting from 0) |
|||
value |
[False, True] |
bool |
Whether the respective function shall be activated or deactivated |
PotiConfigΒΆ
Configuration of the Poti channel
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
internalResistance |
int |
Resistance of the DUT (Ohm) |
|||
refVoltage |
int |
Reference current (in 0.1V) |
RelayΒΆ
Relay
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
value |
[False, True] |
bool |
Whether the respective function shall be activated or deactivated |
SetCurrentΒΆ
Set a current for the Poti channel
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
channelNo |
12 |
int |
Channel number (per board, counting from 0) |
||
current |
float |
Current in milliampere |
SetRawPotiΒΆ
Set the Poti
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
rawPoti |
int |
Poti raw value |
ShortGndΒΆ
Short to ground
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
channelNo |
int |
Channel number (per board, counting from 0) |
|||
value |
[False, True] |
bool |
Whether the respective function shall be activated or deactivated |
ShortVBatΒΆ
Short to battery plus
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
channelNo |
int |
Channel number (per board, counting from 0) |
|||
value |
[False, True] |
bool |
Whether the respective function shall be activated or deactivated |
SwitchSimΒΆ
Resistor
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
boardNo |
int |
Board ID (last octet of the IP address) |
|||
channelNo |
int |
Channel number (per board, counting from 0) |
|||
value |
[False, True] |
bool |
Whether the respective function shall be activated or deactivated |