Skip to content
logo
ecu.test 2025.3 Help
Port BUSACCESS - FLX-OfflineLogging 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: Morphée
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
        • Ports
          • Port BUSACCESS - CAN-OnlineLogging 🛈
          • Port BUSACCESS - CAN-OfflineLogging 🛈
          • Port BUSACCESS - LIN-OnlineLogging 🛈
          • Port BUSACCESS - LIN-OfflineLogging 🛈
          • Port ELECTRICERRORSIM - CANWAY 🛈
          • Port BUSACCESS - FLX-OnlineLogging 🛈
          • Port BUSACCESS - FLX-OfflineLogging 🛈
            • Stimulation
            • Properties 🛈
            • Jobs 🛈
              • ClearFrame
              • DeregisterFrameForInbox
              • GetFirstValue
              • InitFrame
              • ReadFrame
              • ReadFrameEx
              • RegisterFrameForInbox
              • ResetFirstValue
              • SetFlowControlCTS
              • SetFlowControlWait
              • SwitchBusState
          • Port BUSACCESS - CAN-Recording 🛈
          • Port BUSACCESS - FLX-Recording 🛈
          • Port BUSACCESS - LIN-Recording 🛈
          • Port SERVICEACCESS - ETHERNET-Recording 🛈
          • Port DIAGNOSTICS - CAN 🛈
          • Port DIAGNOSTICS - J1939 🛈
          • Port APPLICATION - XCP-CAN 🛈
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Properties 🛈
    • Jobs 🛈
      • ClearFrame
      • DeregisterFrameForInbox
      • GetFirstValue
      • InitFrame
      • ReadFrame
      • ReadFrameEx
      • RegisterFrameForInbox
      • ResetFirstValue
      • SetFlowControlCTS
      • SetFlowControlWait
      • SwitchBusState

    Port BUSACCESS - FLX-OfflineLogging 🛈¶

    Access to FlexRay in the test case, with recording on the Logger

    Stimulation¶

    This port supports all features described in Stimulation control.

    Properties 🛈¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel number

    ‘1’

    string

    Selection of channel number if there is more than one controller of same type.

    Bus-DB

    string

    Placeholder value for automatic E2E calculation

    int

    Whenever this value is specified for an E2E signal (e.g. CRC), upon transmission ecu.test automatically replaces it with the correct, calculated value. The purpose of this option is to allow transmission of arbitrary fixed values (unequal to the value chosen here). Leaving this option empty completely disables the feature.

    Automatic start/stop

    ‘Test execution’

    [‘Test execution’, ‘Configuration start/stop’, ‘Never’]

    string

    This option affects whether the FlexRay controller will be started and stopped automatically. If ‘Never’ is chosen, the controller must be started and stopped explicitly using the port Job ‘SwitchBusState’.

    Caution: all timestamps (e.g. in ASC traces) are relative to the time of the controller start.

    Export format

    ‘ASC’

    [‘DLF’, ‘BLF’, ‘ASC’, ‘PCAP’]

    string

    Save signal recordings in this format

    Jobs 🛈¶

    ClearFrame¶

    Erases the receiving buffer of given frame

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    SlotId

    int

    Frame ID

    StartCycle

    int

    Start cycle

    DeregisterFrameForInbox¶

    Ungeristers a frame that is being streamed to an inbox

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    Inbox

    object

    Existing inbox

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    GetFirstValue¶

    Reads the first received value of the given signal

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameName

    string

    Frame name

    NodeName

    string

    Name of the electronic control unit

    RawValue

    False

    [False, True]

    bool

    If ‘True’, the Raw value is returned.

    reset

    False

    [False, True]

    bool

    If ‘True’ the first received value will be deleted after it has been read

    SignalName

    string

    Signal name

    InitFrame¶

    Initializes the given frame

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    DataLength

    int

    Length in words

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    ReadFrame¶

    Reads the given frame (use InitFrame before!)

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    doDelete

    False

    [False, True]

    bool

    Deletes the Frame after reading if “True”

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    ByteStream

    ByteStream

    ReadFrameEx¶

    Reads the given frame (use InitFrame before!)

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    doDelete

    False

    [False, True]

    bool

    Deletes the Frame after reading if “True”

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    FlexRayFrame

    RegisterFrameForInbox¶

    Registers a frame to be streamed to an inbox.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    Inbox

    object

    Existing inbox

    saveAsFlxFrame

    False

    [False, True]

    bool

    If True, the frame is saved as a FlexRayFrame object, else as a ByteStream

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    ResetFirstValue¶

    Erases the first received value of the given signal

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameName

    string

    Frame name

    NodeName

    string

    Name of the electronic control unit

    SignalName

    string

    Signal name

    SetFlowControlCTS¶

    Activates to always send a Flow Control “ContinueToSend” message in response to a segmented request. Also new values can be assigned to the internal parameters BlockSize, MNPC and SCexp.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    BlockSize

    int

    Block size in bytes; maximum number of bytes that may be transmitted in the following consecutive frames before the sender has to wait for another flow control frame. - Integer

    If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept.

    MNPC

    int

    MNPC specifies how many consecutive frames the receiver can process within one FlexRay cycle. With MNPC set to 0 the sender can utilize the maximum possible band width. - Integer

    If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept.

    SCexp

    int

    SC defines the minimum distance in cycles until the sender is allowed to send the next consecutive frame. SC = 2^SCexp - 1 - Integer

    If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept.

    SessionId

    object

    Handle of the diagnostic session. This can be either the name of the SUT specified in the TCF, the handle returned by the OpenDiagSession job or None (can only be used if there is one SUT specified).

    SetFlowControlWait¶

    Activates to always send a Flow Control “Wait” messages in response to a segmented request. Note: While activated no segmented message can be received. Use the Job SetFlowControlCTS to reset this behaviour.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    SessionId

    object

    Handle of the diagnostic session. This can be either the name of the SUT specified in the TCF, the handle returned by the OpenDiagSession job or None (can only be used if there is one SUT specified).

    WaitTimeInterval

    0

    int

    Wait time interval in ms. If set to 0, Flow Control “Wait” messages are only sent once, to respond to a segmented request. If set to a value greater than 0, Flow Control “Wait” messages will be sent periodically with the given interval in between.

    SwitchBusState¶

    Switches the FlexRay controller on or off.

    Caution: switching the controller on will reset the ASC timestamps. Recording during the stop and start of the controller may result in an ASC file which violates the monotony of timestamps.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    State

    ‘Off’

    [‘Off’, ‘On’]

    string

    New state of the bus

    2025-12-05
    Previous
    Port BUSACCESS - FLX-OnlineLogging 🛈
    Next
    Port BUSACCESS - CAN-Recording 🛈
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH
    legal notice privacy policy