Skip to content
logo
ecu.test 2025.3 Help
Port BUSACCESS - GENERIC 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: MorphĂ©e
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
        • Ports
          • Port MODELACCESS 🛈
          • Port BUSACCESS - GENERIC 🛈
            • Stimulation
            • Properties 🛈
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Properties 🛈

    Port BUSACCESS - GENERIC đŸ›ˆÂ¶

    Generic bus access

    Stimulation¶

    Stimulation of bus signals is performed via the model access and is only possible if this also supports stimulation. The restrictions/comments of the model access also apply to the generic bus access.

    Restrictions:

    • Stimulus input signals are not supported.

    • Trace files being referenced by a DataFileSegment in an STI file are not converted automatically by ecu.test.

    • It is up to the user to check whether the trace format being used is supported by the tool.

    Properties đŸ›ˆÂ¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Bus identifier

    string

    Logical name of the bus system

    Model port

    string

    Port ID (e.g. “MDL01”) of the model port via which the model access is to be performed. This property can remain empty if there is exactly one model port. If there is more than one model port, this property must be set.

    Bus-DB

    string

    Bus-database (This bus-database is usually taken from the test configuration. Please note that the bus-database is not automatically transferred to the tool, but must be stored there manually.)

    Bus path

    ‘masterappl/Model Root/userinterface_master/disp/io/sg_info’

    string

    Base path of the model variables for the bus signals and messages. The Rx and Tx path specifications refer to this base path.

    ALIVE naming pattern

    ‘ALIV*’

    string

    Pattern for the recognition of ALIVE signals. ? stands for a single character, * for one or more characters.

    CRC naming pattern

    ‘CRC*’

    string

    Pattern for the recognition of CRC signals. ? stands for a single character, * for one or more characters.

    Raw to phys conversion behavior

    ‘error’

    [‘error’, ‘identical’, ‘first’, ‘firstOrIdentical’]


    Display values:

    • ‘error’: ‘not allowed’

    • ‘identical’: ‘identical’

    • ‘first’: ‘first conversion function’

    • ‘firstOrIdentical’: ‘first conversion function or identical’

    string

    Behavior for conversions of raw values in domains without a specified conversion rule. This option should be set according to how the model represents signal values that have no physical representation. By default, such values are not allowed.

    The option “identical” treats raw values directly as phys values.

    The “first conversion function” applies the first defined conversion function on the raw value even if it is not defined for that value.

    The “first conversion function or identical” option uses a first conversion function, if available, or the raw value if no conversion function is defined.

    Rx path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s/Out1’

    string

    Pattern of model path for signal reading

    Tx path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s/const_const/Value’

    string

    Pattern of model path for signal manipulation

    Tx-Switch path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s/const_switch/Value’

    string

    Pattern of model path to the switch for signal manipulation

    CRC-Tx path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s_valid/const_const/Value’

    string

    Pattern of model path for manipulation of a CRC signal

    CRC-Tx-switch path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s_valid/const_switch/Value’

    string

    Pattern of model path for enabling and disabling manipulation of a CRC signal

    ALIVE-Tx path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s_valid/const_const/Value’

    string

    Pattern of model path for manipulation of an ALIVE signal

    ALIVE-Tx-switch path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s_valid/const_switch/Value’

    string

    Pattern of model path for enabling and disabling manipulation of an ALIVE signal

    Tx frame enable path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/enable/const_const/Value’

    string

    Pattern of model path for enabling and disabling a frame

    Ignore missing *-Tx switch path

    ☐

    bool

    If the *-Tx switch path is missing in the model, do not generate an error and restore the value of the *-Tx path to reset.

    Restore behaviour

    ‘DEFAULT’

    [‘DEFAULT’, ‘SWITCH_MODEL’]

    string

    If this property is set to DEFAULT, upon restoring a bus signal, both switch and const value are reset to their initial values. The setting SWITCH_MODEL however causes the switch to always be reset to “use the calculated value”. The const value is not changed.

    2025-12-05
    Previous
    Port MODELACCESS 🛈
    Next
    PEAK: PCAN
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH