Skip to content
logo
ecu.test 2025.3 Help
Port BUSACCESS - GENERIC 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: MorphĂ©e
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
        • Ports
          • Port MODELACCESS - DEFAULT 🛈
          • Port APPLICATION - DEFAULT 🛈
          • Port BUSACCESS - GENERIC 🛈
            • Stimulation
            • Specifics
            • Properties 🛈
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Specifics
    • Properties 🛈

    Port BUSACCESS - GENERIC đŸ›ˆÂ¶

    Generic bus access

    Stimulation¶

    Stimulation of bus signals is performed via the model access and is only possible if this also supports stimulation. The restrictions/comments of the model access also apply to the generic bus access.

    Restrictions:

    • Stimulus input signals are not supported.

    • Trace files being referenced by a DataFileSegment in an STI file are not converted automatically by ecu.test.

    • It is up to the user to check whether the trace format being used is supported by the tool.

    Specifics¶

    With this port type you can read and manipulate bus quantities (frames and signals) that are represented in the model. The mapping for bus signals to model data is described in the test bench configuration. The corresponding syntax is described in the following section.

    Port type BUSACCESS GENERIC

    Bus port for access to the rest bus simulation of the environment model. The representation of signal/message names on model paths can be largely configured by means of path patterns. The representation of CRC and ALIVE signals is configured separately. CRC and ALIVE signals can be recognized by the prefixes “CRC” or “ALIV” in the signal names.

    Path like properties might contain certain placeholders. Those will be automatically replaced when accessing bus signals. A placeholder always begins with the character “%” and is enclosed by parenthesis, like so: %(<placeholder>). The closing parenthesis has to be followed by a formatter.

    Info

    A valid expression could be e.g %(signal)s, where “signal” is a placeholder and “s” is a formatter.

    Available placeholders

    bus

    Name of the bus

    node

    Name of the control unit

    frame

    Name of the message / frame

    frameId

    Numeric ID of the message / frame

    CAN: CAN ID FlexRay: Slot ID

    pdu

    Name of the PDU / subframe

    signal

    Name of the signal

    cycleRepetition

    FlexRay only: The number of cycles after which a frame is sent again

    baseCycle

    FlexRay only: The first communication cycle in which a frame is sent

    segmentType

    FlexRay only: “Dynamic” if the current slot id is greater than the number of static slots, else “Static”

    signalGroup

    Name of the signalgroup

    Formatters

    The placeholders can be formatted using the following formatting rules:

    s

    placeholder is just replaced, case sensitive spelling of value to be replaced remains unchanged

    us

    replaced value is completely converted into upper-case letters

    ls

    replaced value is completely converted into lower-case letters

    d

    replaced value is represented in decimal format

    x

    replaced value is represented in hex format with lower-case letters

    X

    replaced value is represented in hex format with upper-case letters

    4x

    replaced value is expanded to 4 digits with leading zeros (number of digits can be changed, and combination with X or d instead of x is also possible)

    Marking parts of a path as optional

    It is possible to mark certain parts of a path as optional. A part is optional if it:

    • is placed between squared brackets and

    • it contains at least one place holder

    An optional part will be left out if any of the contained placeholders is evaluated to an empty string.

    For example: A TX path has been configured as /can/[%(signalGroup)s/]%(signal)s/Value. Assuming a signal “A” belonging to signal group “sign_group”, manipulating it will result in the following model path: /can/sign_group/A/Value. The optional part is kept in the final path. But if the signal is not in a signal group, the path will result in /can/A/value.

    Tx-Switch Path

    The Tx-Switch path is used to de/-activate the manipulation of signals. The Switch path signal is set to the following values, to control the manipulation of the target signal:

    • 0: if the target signal is not manipulated

    • 1: if the target signal is written in Representation Physical conversion

    • 2: if the target signal is written in Representation Raw value

    If Ignore missing *-Tx switch path is set, the Tx-Switch path may be non-existent. The target signal will still be written with the desired value.

    Properties đŸ›ˆÂ¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Bus identifier

    string

    Logical name of the bus system

    Model port

    string

    Port ID (e.g. “MDL01”) of the model port via which the model access is to be performed. This property can remain empty if there is exactly one model port. If there is more than one model port, this property must be set.

    Bus-DB

    string

    Bus-database (This bus-database is usually taken from the test configuration. Please note that the bus-database is not automatically transferred to the tool, but must be stored there manually.)

    ALIVE naming pattern

    ‘ALIV*’

    string

    Pattern for the recognition of ALIVE signals. ? stands for a single character, * for one or more characters.

    CRC naming pattern

    ‘CRC*’

    string

    Pattern for the recognition of CRC signals. ? stands for a single character, * for one or more characters.

    Raw to phys conversion behavior

    ‘error’

    [‘error’, ‘identical’, ‘first’, ‘firstOrIdentical’]


    Display values:

    • ‘error’: ‘not allowed’

    • ‘identical’: ‘identical’

    • ‘first’: ‘first conversion function’

    • ‘firstOrIdentical’: ‘first conversion function or identical’

    string

    Behavior for conversions of raw values in domains without a specified conversion rule. This option should be set according to how the model represents signal values that have no physical representation. By default, such values are not allowed.

    The option “identical” treats raw values directly as phys values.

    The “first conversion function” applies the first defined conversion function on the raw value even if it is not defined for that value.

    The “first conversion function or identical” option uses a first conversion function, if available, or the raw value if no conversion function is defined.

    Rx path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s/Out1’

    string

    Pattern of model path for signal reading

    Tx path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s/const_const/Value’

    string

    Pattern of model path for signal manipulation

    Tx-Switch path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s/const_switch/Value’

    string

    Pattern of model path to the switch for signal manipulation

    CRC-Tx path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s_valid/const_const/Value’

    string

    Pattern of model path for manipulation of a CRC signal

    CRC-Tx-switch path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s_valid/const_switch/Value’

    string

    Pattern of model path for enabling and disabling manipulation of a CRC signal

    ALIVE-Tx path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s_valid/const_const/Value’

    string

    Pattern of model path for manipulation of an ALIVE signal

    ALIVE-Tx-switch path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/%(signal)s_valid/const_switch/Value’

    string

    Pattern of model path for enabling and disabling manipulation of an ALIVE signal

    Tx frame enable path

    ‘%(node)s/kommunikation/%(bus)s/%(frame)s/enable/const_const/Value’

    string

    Pattern of model path for enabling and disabling a frame

    Ignore missing *-Tx switch path

    ☐

    bool

    If the *-Tx switch path is missing in the model, do not generate an error and restore the value of the *-Tx path to reset.

    Restore behaviour

    ‘DEFAULT’

    [‘DEFAULT’, ‘SWITCH_MODEL’]

    string

    If this property is set to DEFAULT, upon restoring a bus signal, both switch and const value are reset to their initial values. The setting SWITCH_MODEL however causes the switch to always be reset to “use the calculated value”. The const value is not changed.

    2025-12-05
    Previous
    Port APPLICATION - DEFAULT 🛈
    Next
    Synopsys: SilverXIL
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH