Skip to content
logo
ecu.test 2025.3 Help
Port SERVICEACCESS - SERVICE_MANAGER πŸ›ˆ
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
        • Ports
          • Port MODELACCESS - DEFAULT πŸ›ˆ
          • Port ELECTRICERRORSIM - DEFAULT πŸ›ˆ
          • Port BUSACCESS - GENERIC πŸ›ˆ
          • Port BUSACCESS - GENERIC_MAPPINGFILE πŸ›ˆ
          • Port BUSACCESS - GENERIC_SOCKETADAPTOR πŸ›ˆ
          • Port BUSACCESS - BUS_MANAGER πŸ›ˆ
          • Port SERVICEACCESS - SERVICE_MANAGER πŸ›ˆ
            • Stimulation
            • Properties πŸ›ˆ
          • Port BUSACCESS - MODEL BASED πŸ›ˆ
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: MorphΓ©e
      • froglogic: Squish
      • Google: ADB
      • GΓΆpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Properties πŸ›ˆ

    Port SERVICEACCESS - SERVICE_MANAGER πŸ›ˆΒΆ

    Service access via model

    StimulationΒΆ

    The stimulation of ServiceEvent signals takes place via the model access and is only possible if this also supports the stimulation. The restrictions/comments of the model access also apply to the generic ServiceManager access.

    Restrictions:

    • Stimulus input signals are not supported.

    • Trace files being referenced by a DataFileSegment in an STI file are not converted automatically by ecu.test.

    • It is up to the user to check whether the trace format being used is supported by the tool.

    Properties πŸ›ˆΒΆ

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Path to the configuration file

    string

    This file on the tool host defines templates to find the matching model paths based on service data. Can be absolute or relative to the tool host base path.

    Model port

    string

    Port ID (e.g. β€œMDL01”) of the model port via which the model access is to be performed. This property can remain empty if there is exactly one model port. If there is more than one model port, this property must be set.

    Cycle time ❲ms❳

    100

    int

    Simulation step size of the model. Will be used as waiting time between sequential model access steps if new values need to be calculated within the model. For example, when reading an array the corresponding index is first registered in the model. The correct matching value is only available when it has been calculated by the model after a specified time.

    2025-12-05
    Previous
    Port BUSACCESS - BUS_MANAGER πŸ›ˆ
    Next
    Port BUSACCESS - MODEL BASED πŸ›ˆ
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH
    legal notice privacy policy