Skip to content
logo
ecu.test 2025.3 Help
Port MODELACCESS 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: Morphée
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
        • Ports
          • Port MODELACCESS 🛈
            • Stimulation
            • Supported execution modes
            • Properties 🛈
            • Jobs 🛈
              • GetFmiType
              • GetSampleTime
              • GetSimulationTime
              • SetDebugLogging
              • StartSimulation
              • StopSimulation
          • Port APPLICATION - GENERIC 🛈
          • Port BUSACCESS - GENERIC 🛈
          • Port BUSACCESS - CAN 🛈
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Supported execution modes
    • Properties 🛈
    • Jobs 🛈
      • GetFmiType
      • GetSampleTime
      • GetSimulationTime
      • SetDebugLogging
      • StartSimulation
      • StopSimulation

    Port MODELACCESS 🛈¶

    Stimulation¶

    Restrictions:

    • Stimulus input signals are not supported.

    • Trace files being referenced by a DataFileSegment in an STI file are not converted automatically by ecu.test.

    Supported execution modes¶

    See also: Temporal behaviour: Real time and simulation time modes

    Preferred time source/mode: Stepwise simulation time

    Real-time:

    To use real-time mode, the Test configuration in the Execution tab must be configured as the source ‘real time’.

    Stepwise simulation time:

    To use the stepwise simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to ‘stepwise’.

    Continuous simulation time:

    To use the continuous simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to ‘continuous’.

    Properties 🛈¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FMU file

    string

    Relative path to the FMU file relative to the FMU root directory.

    FMI type

    automatic

    [automatic, CoSimulation, ModelExchange]

    string

    The FMI type to be used for the simulation. If “automatic” is selected, the type defined in the model description is used or “CoSimulation” if the FMU supports both types.

    Validate Model Description

    ☑

    bool

    Validate the Model Description XML against the schema from the FMI standard upon loading?

    Simulation behavior

    Simulation speed

    Simulation behavior

    unthrottled

    [unthrottled, individual, 1x, 2x, 4x, 8x]

    string

    For real-time simulations, the simulation speed can be reduced to a setpoint (multiple of real time).

    individual simulation speed

    Simulation behavior » Simulation speed: ‘individual’

    1.0

    float

    Set individual simulation speed (multiple of real time)

    Communication step size

    Simulation behavior

    automatic

    [automatic, determine from Default Experiment, individual]

    string

    Step size that is used to stimulate signals. Also used as “stepSize” for ModelExchange FMUs with fixed-step solver. If “automatic” is set, the system first tries to determine the step size from the default experiment. If this is not available or no default experiment is defined, 0.001 (1 ms) is used.

    individual communication step size

    Simulation behavior » Communication step size: ‘individual’

    0.001

    float

    define individual communication step size (specified in seconds)

    Downsampling factor for signal recording

    Simulation behavior

    1

    int

    Factor for reducing the data points (samples) when recording signals. The factor is related to the communication step size and not to the step size with which the FMU calculates internally. With a factor of 10, only every tenth data point is written to the recording. By default, all data points are recorded (factor 1).

    Logging

    Enable debug logging

    Logging

    ☐

    bool

    Enables debug logging for the FMU. This option should be disabled in production because emitting a lot of debug prints may severely affect the simulation performance.

    Enable logging for FMI calls

    Logging

    ☐

    bool

    Enables logging of all FMI calls. This option should be disabled in production because emitting a lot of debug prints may severely affect the simulation performance.

    Jobs 🛈¶

    GetFmiType¶

    Returns the FMI simulation type of the FMU

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    FMI simulation type

    GetSampleTime¶

    Returns the effective communication step size

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    float

    configured step size

    GetSimulationTime¶

    Returns the current simulation time

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    float

    current simulation time

    SetDebugLogging¶

    Enables/disables debug logging for the FMU

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    categories

    object

    List of categories for which logging should be enabled (type: list[str]). (affects both regular log output and debug log output).

    The available categories can be taken from the modelDescription.xml of the FMU.

    ‘None’ or an empty list ‘[]’ will cause the log outputs to be unfiltered, i.e. all log categories will be output.

    loggingOn

    True

    [False, True]

    bool

    Enable/disable debug logging

    StartSimulation¶

    May be used to start the simulation within a package, e.g. if the simulation isn’t started automatically upon package start (see test bench option).

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    /

    No return value

    StopSimulation¶

    May be used to stop the simulation within a package

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    float

    current simulation time

    2025-12-05