Skip to content
logo
ecu.test 2025.3 Help
Port MODELACCESS - SMF_Bosch 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: Morphée
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
        • Ports
          • Port MODELACCESS - Default 🛈
          • Port MODELACCESS - SMF_Bosch 🛈
            • Stimulation
            • Supported execution modes
            • Properties 🛈
            • Jobs 🛈
              • GetFilenamesOfLastRecording
              • LoadParameterFile
              • ReadValue
              • RestartSimulation
              • StartSimulation
              • StopSimulation
              • WriteValue
          • Port FAILURESIM - FIU 🛈
          • Port BUSACCESS - GENERIC 🛈
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Supported execution modes
    • Properties 🛈
    • Jobs 🛈
      • GetFilenamesOfLastRecording
      • LoadParameterFile
      • ReadValue
      • RestartSimulation
      • StartSimulation
      • StopSimulation
      • WriteValue

    Port MODELACCESS - SMF_Bosch 🛈¶

    Model port with Bosch specific SMF representation (based on DGS determinations).

    Stimulation¶

    The following LabCar-side restrictions apply:

    • Up to version 3.7.9, only STI 1.0 can be used for stimulation.

    • As of version 3.7.10, STI 2.0 is also supported.

    • The SignalValueSegment is not supported.

    • Only DAT and MAT files compatible with LabCar can be used as file reference.

    • Only ‘forward’ and ‘linear’ interpolation methods are supported.

    It is mandatory to specify a stimulation task in the test bench configuration. Thereby the use of wildcards (* and ?) is not possible!

    The value for “duration” must not be +INF, but must be set to a concrete numeric value.

    Restrictions:

    • Stimulus input signals are not supported.

    • Trace files being referenced by a DataFileSegment in an STI file are not converted automatically by ecu.test.

    • It is up to the user to check whether the trace format being used is supported by the tool.

    Supported execution modes¶

    See also: Temporal behaviour: Real time and simulation time modes

    Preferred time source/mode: Real-time

    Real-time:

    To use real-time mode, the Test configuration in the Execution tab must be configured as the source ‘real time’.

    Info

    The following modes are not supported: Stepwise simulation time, Continuous simulation time

    Properties 🛈¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Model file

    string

    Model file (.eew)

    Support for online model querying

    ☑

    bool

    (De-)Activates the interface for online querying of model information by the test configuration

    Default acquisition rate

    ‘Tool-Default’

    string

    Declaration of the measurement acquisition rate for signal recordings used as alternative in case no acquisition rate is set in the test step (’*’ and ‘?’ can be used as wildcard). “Tool-Default” activates the use of the standard acquisition rate of the tool. For reading signals, “Asynchronous RTPC Access” is always chosen.

    SMF files

    string

    List of paths of the SMF files which should be used (empty if no SMF files available).

    Paths can be absolute, relative to the model directory or relative to the tool host base path.

    Parameter file paths

    string

    List of absolute paths of parameter files *.dcm and *.mpa to use (leave empty to use none).

    Paths can be absolute, relative to the model directory or relative to the tool host base path.

    Bypass reading buffer

    ☑

    bool

    If this option is set to True, all variables will be read directly from the real-time platform. However, if set to False, accessible values will be read over the LCO buffer. This speeds up the reading process (lower workload) but leads to less accurate values because the buffer is only updated every few (ca. 100) milliseconds.

    Stimulation task

    string

    Stimulation task, that is used for playback of signal generators.

    Switch signals before stimulation

    ☑

    bool

    Determines whether signals are switched to use the signal generator before or after starting the signal generator. True means before, False means after.

    Device used by signal generators

    ‘RTPC’

    string

    Name of the device used for uploading signal generators.

    Display SMF Inport signal elements

    ☑

    bool

    Shows the SMF variables that are abstracted by the SMF inport. If necessary use this setting for old packages that use this option and set it TRUE.

    Jobs 🛈¶

    GetFilenamesOfLastRecording¶

    Returns the file paths of the last recording.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    fileNames

    object

    File path list of the recording files. Can be empty.

    LoadParameterFile¶

    Loads values from a parameter file into the experiment

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FilePath

    string

    Path to the *.dcm or *.mpa file on the tool host

    ReadValue¶

    Reads a value of a variable

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Task

    string

    Task used for registering the value

    VariablePath

    string

    Variable path

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    string

    Numeric return value or NotPresent

    RestartSimulation¶

    Stops and restarts the simulation resetting every previously written values.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Reset

    True

    [False, True]

    bool

    Re-deploys the model on the real-time platform.

    StartSimulation¶

    Starting the simulation of the real-time platform.

    StopSimulation¶

    Stopping the simulation of the real-time platform.

    WriteValue¶

    Writes the value of a variable

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Task

    string

    Task used for registering the value

    Value

    0

    float

    Numeric return value

    VariablePath

    string

    Variable path

    2025-12-05
    Previous
    Port MODELACCESS - Default 🛈
    Next
    Port FAILURESIM - FIU 🛈
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH