Skip to content
logo
ecu.test 2025.3 Help
Port MODELACCESS - DEFAULT 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: Morphée
        • Ports
          • Port MODELACCESS - DEFAULT 🛈
            • Stimulation
            • Supported execution modes
            • Properties 🛈
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Supported execution modes
    • Properties 🛈

    Port MODELACCESS - DEFAULT 🛈¶

    Model access

    Stimulation¶

    This port has no stimulus capabilities.

    Supported execution modes¶

    See also: Temporal behaviour: Real time and simulation time modes

    Preferred time source/mode: Real-time

    Real-time:

    To use real-time mode, the Test configuration in the Execution tab must be configured as the source ‘real time’.

    Info

    The following modes are not supported: Stepwise simulation time, Continuous simulation time

    Properties 🛈¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Support for online model querying

    ☑

    bool

    (De-)Activates the interface for online querying of model information by the test configuration

    Alive signal

    ☐

    bool

    Activates an alive signal on port startup which toggles from 0 to 1 and back.

    Interval

    Alive signal

    1

    int

    The transmission interval in seconds.

    Alive signal variable path

    Alive signal

    string

    The variable path the alive signal is written to.

    Variable path for the connection state

    Alive signal

    string

    This variable is 1 while the port is used for test execution. Meanwhile the alive signal is sent.

    Activate alarm check

    ☐

    bool

    Avoids writing variables if the test bench is in alarm state.

    Alarm state variable path

    Activate alarm check

    string

    Variable path of the alarm state of the test bench. An active Alarm corresponds to a value greater than 0.

    2025-12-05
    Previous
    FEV: Morphée
    Next
    froglogic: Squish
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH
    legal notice privacy policy