Port MODELACCESS - standard ๐ยถ
Use the already activated configuration and the existing program of the automation device.
Stimulationยถ
This port has no stimulus capabilities.
Supported execution modesยถ
See also: Temporal behaviour: Real time and simulation time modes
Preferred time source/mode: Real-time
- Real-time:
To use real-time mode, the Test configuration in the Execution tab must be configured as the source โreal timeโ.
Info
The following modes are not supported: Stepwise simulation time, Continuous simulation time
Properties ๐ยถ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Device NetId |
โ127.0.0.1.1.1โ |
string |
NetId of the automation device |
||
Device port |
801 |
int |
Communication port of the automation device. Default TwinCat 2: 801. Default TwinCat 3: 851. |
||
Access variables by handle |
โ |
bool |
Determines, whether access to variable values is to be carried out by handle. |
||
Support for online model querying |
โ |
bool |
(De-)Activates the interface for online querying of model information by the test configuration |
||
Recording |
|||||
File type for signal recording |
Recording |
โMDFโ |
[โMDFโ, โCSVโ] |
string |
File type for signal recording |
Max. delay for signal query [ms] |
Recording |
50 |
float |
Allowed delay when transmitting changed signal values. Increasing this value leads to a delay when reading signals in ecu.test. When setting this value too low, signal recordings may not contain all signal changes, especially when recording multiple signals with high frequent value changes parallel! |
|
Recording mode |
Recording |
event-based |
[event-based, cyclic] Display values:
|
string |
Mode for signal recordings. Event-based: Data points are created when the signal value changes. Cyclic: Data points are created regarding the configured acquisition rate. |
Default acquisition rate [ms] |
Recording ยป Recording mode: โcyclicโ |
10 |
float |
Default acquisition rate in milliseconds. |
Jobs ๐ยถ
ResetDeviceยถ
Resets the device
StartDeviceยถ
Starts the device
StopDeviceยถ
Stops the device