Skip to content
logo
ecu.test 2025.3 Help
Port BUSACCESS - FLX 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: Morphée
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
        • Ports
          • Port SERVICEACCESS - SERVICE-PASSIVE 🛈
          • Port SERVICEACCESS - SERVICE 🛈
          • Port SERVICEACCESS - TCP-CLIENT-SOCKET 🛈
          • Port SERVICEACCESS - TCP-SERVER-SOCKET 🛈
          • Port SERVICEACCESS - TLS 🛈
          • Port SERVICEACCESS - UDP-SOCKET 🛈
          • Port SERVICEACCESS - ARP 🛈
          • Port BUSACCESS - CAN 🛈
          • Port BUSACCESS - CAN-FD 🛈
          • Port DIAGNOSTICS - CAN-FD 🛈
          • Port DIAGNOSTICS - CAN-FD_TOLERANT 🛈
          • Port DIAGNOSTICS - CAN 🛈
          • Port ELECTRICERRORSIM - CANWAY 🛈
          • Port LOGGING - DLT-VERBOSE 🛈
          • Port SERVICEACCESS - ETHERNET-RAW 🛈
          • Port BUSACCESS - FLX 🛈
            • Stimulation
            • Properties 🛈
            • Jobs 🛈
              • ClearFrame
              • CloseFrTpSession
              • DeregisterFrameForInbox
              • DeregisterStreamForInbox
              • DisableSendFrameCyclic
              • GetFirstValue
              • GracefulShutdown
              • InitFrame
              • OpenFrTpSession
              • ReadFrame
              • ReadFrameEx
              • RegisterFrameForInbox
              • RegisterStreamForInbox
              • ResetFirstValue
              • SendFrame
              • SendFrameCyclic
              • SendStream
              • SetFlowControlCTS
              • SetFlowControlWait
              • StartTimeSyncMaster
              • StopTimeSyncMaster
              • SwitchBusState
              • UpdateTimeSyncMaster
          • Port DIAGNOSTICS - FLX 🛈
          • Port SERVICEACCESS - ICMP-RAW 🛈
          • Port SERVICEACCESS - IPSEC 🛈
          • Port BUSACCESS - LIN 🛈
          • Port SERVICEACCESS - MACSEC 🛈
          • Port MODELACCESS - DEFAULT 🛈
          • Port SERVICEACCESS - RECORDING-PCAP 🛈
          • Port BUSACCESS - SOCKETADAPTOR 🛈
          • Port SERVICEACCESS - UDP-RAW 🛈
          • Port DIAGNOSTICS - DOIP 🛈
          • Port DIAGNOSTICS - J1939 🛈
          • Port DIAGNOSTICS - KWP2000-CAN 🛈
          • Port DIAGNOSTICS - DOSOAD 🛈
          • Port APPLICATION - XCP-CAN-FD-TOLERANT 🛈
          • Port APPLICATION - XCP-CAN-FD 🛈
          • Port APPLICATION - XCP-CAN 🛈
          • Port APPLICATION - XCP-ETH 🛈
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Properties 🛈
    • Jobs 🛈
      • ClearFrame
      • CloseFrTpSession
      • DeregisterFrameForInbox
      • DeregisterStreamForInbox
      • DisableSendFrameCyclic
      • GetFirstValue
      • GracefulShutdown
      • InitFrame
      • OpenFrTpSession
      • ReadFrame
      • ReadFrameEx
      • RegisterFrameForInbox
      • RegisterStreamForInbox
      • ResetFirstValue
      • SendFrame
      • SendFrameCyclic
      • SendStream
      • SetFlowControlCTS
      • SetFlowControlWait
      • StartTimeSyncMaster
      • StopTimeSyncMaster
      • SwitchBusState
      • UpdateTimeSyncMaster

    Port BUSACCESS - FLX 🛈¶

    VECTOR-HW access to FLX

    Stimulation¶

    This port supports all features described in Stimulation control.

    Properties 🛈¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel number

    ‘1’

    string

    Selection of channel number if there is more than one controller of same type.

    Do not stop RBS

    ☐

    bool

    Restbus simulation stays active beyond test case execution.

    Keep TimeMaster active

    ☐

    bool

    DMCS-TimeMaster stays active after test cases have finished. Will be shutdown together with the configuration

    Bus-DB

    string

    Placeholder value for automatic E2E calculation

    int

    Whenever this value is specified for an E2E signal (e.g. CRC), upon transmission ecu.test automatically replaces it with the correct, calculated value. The purpose of this option is to allow transmission of arbitrary fixed values (unequal to the value chosen here). Leaving this option empty completely disables the feature.

    Automatic start/stop

    ‘Test execution’

    [‘Test execution’, ‘Configuration start/stop’, ‘Never’]

    string

    This option affects whether the FlexRay controller will be started and stopped automatically. If ‘Never’ is chosen, the controller must be started and stopped explicitly using the port Job ‘SwitchBusState’.

    Caution: all timestamps (e.g. in ASC traces) are relative to the time of the controller start.

    Reinitialize on loss of bus synchronization

    ☑

    bool

    If this option is set, the FlexRay controller will automatically be reinitialized when it loses synchronization to the bus. Caution: if necessary, the reinitialization is performed even if the option ‘Automatic start/stop’ is set.

    Listen only

    ☐

    bool

    Controller is running in passive mode. Writing is not possible

    Logging of events

    ☐

    bool

    The Events SCE, SE and EE will be written to the ASC file during recording

    Configuration mode

    ‘Bus database’

    [‘Bus database’]

    string

    If there are several methods to configure this port, the one to be used can be chosen here. The mode ‘configuration file’ requires a path in the corresponding setting. The mode ‘bus database’ extracts the required information from the bus database.

    TX ECU names ❲bus database❳

    string

    Comma-separated list of control units, for whose messages tx buffers shall be configured.

    Only needed in the configuration mode ‘bus database’.

    Cold-start node ❲bus database❳

    ‘<auto>’

    [‘<auto>’, ‘no cold-start node’, ‘cold-start node’]

    string

    Decides whether the node shall participate in the cluster start.

    The setting <auto> takes the configuration for the first configured TX ECU from the bus database.

    Only needed in configuration mode ‘bus database’.

    Transmission confirmation

    ☐

    bool

    Activates acknowledged sending. Bus-Write test steps and Send tool jobs block until the message was successfully transferred on the bus or the confirm timeout expired.

    Timeout for transmission confirmation

    1000

    int

    Period in miliseconds in which a message has to be sent successfully. Otherwise an error is created. (must not be larger than 64535ms). Is only used in active confirm mode.

    Null frames

    ☐

    bool

    Null frames will be logged only if ‘True’

    Cold start behavior

    ‘Leader’

    [‘Leader’, ‘Follower’, ‘Both’]

    string

    Behavior of the port during cold start. If the port is to be ‘Leader’ and ‘Follower’, the option ‘Both’ can be selected. In this case the Vector Advanced XL driver library must be installed.

    Spy mode

    ☐

    bool

    In this mode no writing is possible.

    Instead of the complete FlexRay configuration, only the baud rate is needed.

    Baudrate ❲only relevant for spy mode❳

    ‘10 Mbit/s’

    [‘10 Mbit/s’, ‘5 Mbit/s’, ‘2.5 Mbit/s’]

    string

    Jobs 🛈¶

    ClearFrame¶

    Erases the receiving buffer of given frame

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    SlotId

    int

    Frame ID

    StartCycle

    int

    Start cycle

    CloseFrTpSession¶

    Closes the FrTP session.

    Parameterization

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    return

    [False, True]

    bool

    Session successfully closed

    DeregisterFrameForInbox¶

    Ungeristers a frame that is being streamed to an inbox

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    Inbox

    object

    Existing inbox

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    DeregisterStreamForInbox¶

    Deregisters a FrTp session.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    conId

    int

    Connection ID

    DisableSendFrameCyclic¶

    Deactivate cyclic transmission of a message with given id

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    SlotId

    int

    Frame ID

    StartCycle

    int

    Start cycle

    GetFirstValue¶

    Reads the first received value of the given signal

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameName

    string

    Frame name

    NodeName

    string

    Name of the electronic control unit

    RawValue

    False

    [False, True]

    bool

    If ‘True’, the Raw value is returned.

    reset

    False

    [False, True]

    bool

    If ‘True’ the first received value will be deleted after it has been read

    SignalName

    string

    Signal name

    GracefulShutdown¶

    Shut down the bus the stated number of cycles after the last transmission of the message identified by the parameters. The actual message may have a more frequent cycle configuration, in which case a transmission matching the specified parameters is chosen as the final one. Optionally, a different payload can be specified for the final transmission. Uses driver support for delayed shutdown if available.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    NCycles

    int

    Number of cycles

    PayloadForFinalTransmission

    ByteStream

    Different payload for final transmission. If specified, the final transmission will use this payload. If not, the final transmission will use the payload it would have used if this job hadn’t been called.

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    InitFrame¶

    Initializes the given frame

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    DataLength

    int

    Length in words

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    OpenFrTpSession¶

    Opens a FlexRay TP session.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    acknowledged

    False

    [False, True]

    bool

    The acknowledge bit (C_CT communication type) signals whether the sender requires a confirmation of receipt (acknowledged, STFA) or not (unacknowledged, STFU). - Integer

    blockSize

    0

    int

    Block size in bytes; maximum number of bytes that may be transmitted in the following consecutive frames before the sender has to wait for another flow control frame. - Integer

    fillByte

    ByteStream

    Byte to fill messages (optional) - ByteStream of length 1

    flowControlAddr

    -1

    int

    Different address of the control unit (ECU) for FlowControl - Hex (optional Integer)

    maxFrameLength

    0

    int

    Maximum length of a frame in bytes (applies to both start, consecutive and last frames); if this value is set to 0, the maximum value described in ISO 10681-2 is used - Integer

    mnpc

    0

    int

    MNPC specifies how many consecutive frames the receiver can process within one FlexRay cycle. With MNPC set to 0 the sender can utilize the maximum possible band width. - Integer

    requestBaseCycle

    int

    Cycle offset in the application cycle window - Integer < RequestCycleRepetition

    requestCycleRepetition

    int

    Cycle count after which the frame is sent periodically based on BaseCycle - Integer >= 1

    requestSlotId

    int

    Frame-ID for requests sent to the ECU - 1 or 2 byte Hex (integer)

    responseBaseCycle

    int

    Cycle offset in the application cycle window - Integer < ResponseCycleRepetition

    responseCycleRepetition

    int

    Cycle count after which the frame is received periodically based on BaseCycle - Integer >= 1

    responseSlotId

    int

    Frame-ID for ECU responses - 1 or 2 byte Hex (integer)

    scExp

    0

    int

    SC defines the minimum distance in cycles until the sender is allowed to send the next consecutive frame. SC = 2^SCexp - 1 - Integer

    sourceAddr

    int

    Address of the tester (ecu.test) - Hex (integer)

    targetAddr

    int

    Address of the ECU - Hex (integer)

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    return

    int

    Connection ID

    ReadFrame¶

    Reads the given frame (use InitFrame before!)

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    doDelete

    False

    [False, True]

    bool

    Deletes the Frame after reading if “True”

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    ByteStream

    ByteStream

    ReadFrameEx¶

    Reads the given frame (use InitFrame before!)

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    doDelete

    False

    [False, True]

    bool

    Deletes the Frame after reading if “True”

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    FlexRayFrame

    RegisterFrameForInbox¶

    Registers a frame to be streamed to an inbox.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    Inbox

    object

    Existing inbox

    saveAsFlxFrame

    False

    [False, True]

    bool

    If True, the frame is saved as a FlexRayFrame object, else as a ByteStream

    SlotId

    int

    Frame ID

    StartCycle

    int

    StartCycle (cycle offset)

    RegisterStreamForInbox¶

    Registers a FrTp session to be streamed to an inbox.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    conId

    int

    Connection ID

    inbox

    object

    Existing inbox

    ResetFirstValue¶

    Erases the first received value of the given signal

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameName

    string

    Frame name

    NodeName

    string

    Name of the electronic control unit

    SignalName

    string

    Signal name

    SendFrame¶

    Sends the given frame ID. Frame ID must be registered in advance via the job “InitFrame”.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    CycleRepetition

    int

    Cycle repetition

    Data

    string

    data to be send

    SlotId

    int

    Frame ID

    StartCycle

    int

    Start cycle

    SendFrameCyclic¶

    Cyclic transmission of a message with given ID and data. Message ID must be registered in advance via the job “InitFrame”.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Channel

    ‘A’

    [‘A’, ‘B’, ‘*’]

    string

    FlexRay Channel (A, B or *)

    Count

    int

    Number of sending repetitions

    CycleRepetition

    int

    Cycle repetition

    DataByteStream

    ByteStream

    data to be send

    Interval

    int

    Cycle time in ms; 0 for every cycle

    SlotId

    int

    Frame ID

    StartCycle

    int

    Start cycle

    SendStream¶

    Send a data stream via FrTp.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    conId

    int

    Connection ID

    data

    object

    Payload to be sent via FrTp

    timeout

    int

    Timeout for sending the message in milliseconds

    SetFlowControlCTS¶

    Activates to always send a Flow Control “ContinueToSend” message in response to a segmented request. Also new values can be assigned to the internal parameters BlockSize, MNPC and SCexp.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    BlockSize

    int

    Block size in bytes; maximum number of bytes that may be transmitted in the following consecutive frames before the sender has to wait for another flow control frame. - Integer

    If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept.

    MNPC

    int

    MNPC specifies how many consecutive frames the receiver can process within one FlexRay cycle. With MNPC set to 0 the sender can utilize the maximum possible band width. - Integer

    If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept.

    SCexp

    int

    SC defines the minimum distance in cycles until the sender is allowed to send the next consecutive frame. SC = 2^SCexp - 1 - Integer

    If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept.

    SessionId

    object

    Handle of the diagnostic session. This can be either the name of the SUT specified in the TCF, the handle returned by the OpenDiagSession job or None (can only be used if there is one SUT specified).

    SetFlowControlWait¶

    Activates to always send a Flow Control “Wait” messages in response to a segmented request. Note: While activated no segmented message can be received. Use the Job SetFlowControlCTS to reset this behaviour.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    SessionId

    object

    Handle of the diagnostic session. This can be either the name of the SUT specified in the TCF, the handle returned by the OpenDiagSession job or None (can only be used if there is one SUT specified).

    WaitTimeInterval

    0

    int

    Wait time interval in ms. If set to 0, Flow Control “Wait” messages are only sent once, to respond to a segmented request. If set to a value greater than 0, Flow Control “Wait” messages will be sent periodically with the given interval in between.

    StartTimeSyncMaster¶

    Starts the time synchronization as TimeMaster via FlexRay - A maximum of one TimeMaster should be active on a bus at all times

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    BaseCycle

    0

    int

    BaseCycle for the sync frames

    Channel

    ‘A’

    [‘A’, ‘B’, ‘AB’]

    string

    Channel for the sync frames

    CycleRepetition

    1

    int

    CycleRepetition for the sync frames

    HwTimstampOffset

    0

    int

    Offset in nanoseconds (positive or negative) that gets added to hardware timestamps

    SequenceCounterFreeze

    False

    [False, True]

    bool

    Freeze the SequenceCounter

    SequenceCounterInit

    0

    int

    Start value of SequenceCounter

    SlotID

    int

    Slot ID for the sync frames

    SyncDataId

    object

    Data ID for SYNC messages for identification during CRC calculation (list with 16 integers)

    SyncInterval

    900000000

    int

    Interval in nanoseconds between two Sync frames

    TimeDomain

    int

    Specifies the time domain which should be synchronized

    UserByte0

    0x00

    int

    Optional byte of user data

    UserByte1

    0x00

    int

    Optional byte of user data

    StopTimeSyncMaster¶

    Stoppt die Zeitsynchronisation als TimeMaster über FlexRay

    SwitchBusState¶

    Switches the FlexRay controller on or off.

    Caution: switching the controller on will reset the ASC timestamps. Recording during the stop and start of the controller may result in an ASC file which violates the monotony of timestamps.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    State

    ‘Off’

    [‘Off’, ‘On’]

    string

    New state of the bus

    UpdateTimeSyncMaster¶

    Will update the parameters if the TimeMaster is running.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    BaseCycle

    0

    int

    BaseCycle for the sync frames

    Channel

    ‘A’

    [‘A’, ‘B’, ‘AB’]

    string

    Channel for the sync frames

    CycleRepetition

    1

    int

    CycleRepetition for the sync frames

    HwTimstampOffset

    0

    int

    Offset in nanoseconds (positive or negative) that gets added to hardware timestamps

    SequenceCounterFreeze

    False

    [False, True]

    bool

    Freeze the SequenceCounter

    SequenceCounterInit

    0

    int

    Start value of SequenceCounter

    SlotID

    int

    Slot ID for the sync frames

    SyncDataId

    object

    Data ID for SYNC messages for identification during CRC calculation (list with 16 integers)

    SyncInterval

    900000000

    int

    Interval in nanoseconds between two Sync frames

    TimeDomain

    int

    Specifies the time domain which should be synchronized

    UserByte0

    0x00

    int

    Optional byte of user data

    UserByte1

    0x00

    int

    Optional byte of user data

    2025-12-05
    Previous
    Port SERVICEACCESS - ETHERNET-RAW 🛈
    Next
    Port DIAGNOSTICS - FLX 🛈
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH
    legal notice privacy policy