Port ELECTRICERRORSIM - DEFAULT πΒΆ
XIL-API-EESPort
StimulationΒΆ
This port has no stimulus capabilities.
SpecificsΒΆ
Provides a port for access to the EES port interface.
The .portconfig file that is needed to configure the EES port can be generated using ControlDesk. Please refer to the HelpDesk of ControlDesk for more information.
The .portconfig file must have a valid potential mapping and signal mapping section.
To use the EES port, you will need a βPlatform API Licenseβ for ControlDesk. You can check the licenses in the βLicensingβ tab of the dSPACE Installation Manager.
Properties πΒΆ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Configuration file |
string |
Path to the configuration file of the EES port. Path has to be either absolute, or relative to the EES directory. If <auto>, the configuration file referenced by the TCF will be used. Otherwise this setting will take precedence over the path that is configured in the TCF. |
|||
Clear errors at end of test case |
β |
bool |
βTrueβ enables automatic deletion of all electrical errors at the end of each test case and restoring the error-free state of the EES hardware. Select βFalseβ to make electrical errors not deleted by the test case persist beyond the end of the test case. |
Jobs πΒΆ
GetActiveErrorCountΒΆ
Returns the number of Error objects in the currently active ErrorSet. If no ErrorSet is active, -1 is returned.
Parameterization
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
return |
int |
ResetErrorsΒΆ
Clears all errors by appending an empty ErrorSet to the ErrorConfiguration and triggering that ErrorSet.