Skip to content
logo
ecu.test 2025.3 Help
Port MODELACCESS - NO_HILAPI 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
        • Ports
          • Port BUSACCESS - GENERIC 🛈
          • Port BUSACCESS - GENERIC_MAPPINGFILE 🛈
          • Port BUSACCESS - GENERIC_SOCKETADAPTOR 🛈
          • Port BUSACCESS - BUS_MANAGER 🛈
          • Port SERVICEACCESS - SERVICE_MANAGER 🛈
          • Port MODELACCESS - DEFAULT 🛈
          • Port MODELACCESS - NO_HILAPI 🛈
            • Stimulation
            • Supported execution modes
            • Properties 🛈
            • Jobs 🛈
              • ReadVariable
              • WriteVariable
          • Port ELECTRICERRORSIM - DEFAULT 🛈
          • Port FAILURESIM - DEFAULT 🛈
          • Port FAILURESIM - CANWAY 🛈
          • Port FAILURESIM - CANWAY BUSMANAGER 🛈
          • Port APPLICATION 🛈
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: Morphée
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Supported execution modes
    • Properties 🛈
    • Jobs 🛈
      • ReadVariable
      • WriteVariable

    Port MODELACCESS - NO_HILAPI 🛈¶

    without HiL-API access. This port type does not support stimulation.

    Stimulation¶

    This port has no stimulus capabilities.

    Supported execution modes¶

    See also: Temporal behaviour: Real time and simulation time modes

    Preferred time source/mode: Real-time

    Real-time:

    To use real-time mode, the Test configuration in the Execution tab must be configured as the source ‘real time’.

    Stepwise simulation time:

    To use the stepwise simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to ‘stepwise’.

    Info

    The following modes are not supported: Continuous simulation time

    Properties 🛈¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Platform name

    ‘SCALEXIO’

    string

    Name of the platform as specified in the Experiment. Alternatively the platform name in the ControlDesk Platform Management can be used.

    dSPACE RTT Version

    ‘<auto>’

    [‘1.7’, ‘1.8’, ‘1.9’, ‘2.0’, ‘2.1’, ‘2.2’, ‘2.3’, ‘2.4’, ‘2.5’, ‘2.6’, ‘3.0’, ‘3.1’, ‘3.2’, ‘3.3’, ‘3.4’, ‘4.0’, ‘4.1’, ‘4.2’, ‘4.3’, ‘4.4’, ‘5.0’, ‘5.1’, ‘5.2’, ‘22.2’, ‘23.1’, ‘23.2’, ‘24.1’, ‘<auto>’]

    string

    Product version of dSPACE Real-Time Testing

    Support for online model querying

    ☐

    bool

    (De-)Activates the interface for online querying of model information by the test configuration

    Model file

    uri

    Path relative to the model directory

    Loading behavior on reduced compatibility

    ‘cancel’

    [‘cancel’, ‘fix and download’, ‘ignore’]


    Display values:

    • ‘cancel’: ‘Cancel’

    • ‘fix and download’: ‘Fix reduced compatibility and download’

    • ‘ignore’: ‘Ignore reduced incompatibility’

    string

    Behavior of loading on reduced compatibility between model and SCALEXIO System

    Download model

    ‘download’

    [‘download’, ‘no download’]


    Display values:

    • ‘download’: ‘Download always’

    • ‘no download’: ‘Do not download’

    string

    Download model automatically

    Start model

    ‘start’

    [‘start’, ‘no start’]


    Display values:

    • ‘start’: ‘Start’

    • ‘no start’: ‘Do not start’

    string

    Start model automatically after loading (only SCALEXIO)

    Recording task

    ‘Tool-Default’

    string

    Recording acquisition rate to use as fallback, if there is no given acquisition rate for the test value (’*’ and ‘?’ may be used as wildcards).

    “Tool-Default” uses the first available acquisition rate.

    Use common recorder

    ☐

    bool

    Defines whether signals of this port should be recorded together with those of other ports of this tool. This guarantees a common time base and creates a single recording file. Otherwise a separate recording file is created.

    Jobs 🛈¶

    ReadVariable¶

    Read model variables

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    VariablePath

    uri

    full model path

    WriteVariable¶

    Write model variables

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Value

    string

    VariablePath

    uri

    full model path

    2025-12-05
    Previous
    Port MODELACCESS - DEFAULT 🛈
    Next
    Port ELECTRICERRORSIM - DEFAULT 🛈
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH
    legal notice privacy policy