ecu.test 2025.3 Help
Port MODELACCESS - DEFAULT 🛈
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
        • Ports
          • Port BUSACCESS - GENERIC 🛈
          • Port BUSACCESS - GENERIC_MAPPINGFILE 🛈
          • Port BUSACCESS - GENERIC_SOCKETADAPTOR 🛈
          • Port BUSACCESS - BUS_MANAGER 🛈
          • Port SERVICEACCESS - SERVICE_MANAGER 🛈
          • Port MODELACCESS - DEFAULT 🛈
            • Stimulation
            • Supported execution modes
            • Specifics
            • Properties 🛈
            • Jobs 🛈
              • ExecuteTargetScript
              • GetStimulationState
              • ReadVariable
              • WriteVariable
          • Port MODELACCESS - NO_HILAPI 🛈
          • Port ELECTRICERRORSIM - DEFAULT 🛈
          • Port FAILURESIM - DEFAULT 🛈
          • Port FAILURESIM - CANWAY 🛈
          • Port FAILURESIM - CANWAY BUSMANAGER 🛈
          • Port APPLICATION 🛈
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: MorphĂ©e
      • froglogic: Squish
      • Google: ADB
      • Göpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Supported execution modes
    • Specifics
    • Properties 🛈
    • Jobs 🛈
      • ExecuteTargetScript
      • GetStimulationState
      • ReadVariable
      • WriteVariable

    Port MODELACCESS - DEFAULT đŸ›ˆÂ¶

    Default

    Stimulation¶

    DataFileSegment:

    • An absolute path must be provided

    • Only MAT and MF4 can be referenced

    SignalValueSegment:

    • A relative path must be provided

    Supported execution modes¶

    See also: Temporal behaviour: Real time and simulation time modes

    Preferred time source/mode: Real-time

    Real-time:

    To use real-time mode, the Test configuration in the Execution tab must be configured as the source ‘real time’.

    Stepwise simulation time:

    To use the stepwise simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to ‘stepwise’.

    Info

    The following modes are not supported: Continuous simulation time

    Specifics¶

    • To use the default model port port, you will need a “Platform API License” for ControlDesk. You can check the licenses in the “Licensing” tab of the dSPACE Installation Manager.

    • If you are using the simulation time mode, the simulation time is acquired from the variable <activeValueDescription>/Simulation and RTOS/Simulation/SimulationTime which needs to be available in your model.

    Configuration

    The “Platform Name” must always be configured so that ecu.test can access the model. Please note that this option is case-sensitive. The correct identifier can be inspected in a started ControlDesk experiment under Platforms -> Manage Platforms. All other settings are optional. In particular the setting “Model file” should usually be left empty since it is inherited from the test configuration. If you want to connect to an already configured and started ControlDesk, the option “Always reload model” should be set to “Do not download”.

    Info

    As of dSpace ControlDesk 2024-B, real-time testing is no longer supported. Alternatively, you can execute your own Python real-time scripts via the ExecuteTargetScript port job.

    Properties đŸ›ˆÂ¶

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Platform name

    ‘SCALEXIO’

    string

    Name of the platform as specified in the Experiment. Alternatively the platform name in the ControlDesk Platform Management can be used.

    dSPACE RTT Version

    ‘<auto>’

    [‘1.7’, ‘1.8’, ‘1.9’, ‘2.0’, ‘2.1’, ‘2.2’, ‘2.3’, ‘2.4’, ‘2.5’, ‘2.6’, ‘3.0’, ‘3.1’, ‘3.2’, ‘3.3’, ‘3.4’, ‘4.0’, ‘4.1’, ‘4.2’, ‘4.3’, ‘4.4’, ‘5.0’, ‘5.1’, ‘5.2’, ‘22.2’, ‘23.1’, ‘23.2’, ‘24.1’, ‘<auto>’]

    string

    Product version of dSPACE Real-Time Testing

    Support for online model querying

    ☐

    bool

    (De-)Activates the interface for online querying of model information by the test configuration

    Model file

    uri

    Path relative to the model directory

    Loading behavior on reduced compatibility

    ‘cancel’

    [‘cancel’, ‘fix and download’, ‘ignore’]


    Display values:

    • ‘cancel’: ‘Cancel’

    • ‘fix and download’: ‘Fix reduced compatibility and download’

    • ‘ignore’: ‘Ignore reduced incompatibility’

    string

    Behavior of loading on reduced compatibility between model and SCALEXIO System

    Always reload model

    ‘download’

    [‘download’, ‘no download’]


    Display values:

    • ‘download’: ‘Download always’

    • ‘no download’: ‘Do not download’

    string

    If this setting is set to Download always (default value), an already loaded model will be unloaded and the selected model will be reloaded. If the setting is Do not download, an already loaded model will not be unloaded. ControlDesk will return an error message, if the loaded model does not correspond to the selected model.

    Start model

    ‘start’

    [‘start’, ‘no start’]


    Display values:

    • ‘start’: ‘Start’

    • ‘no start’: ‘Do not start’

    string

    Automatic startup of the model after loading

    Model reset behavior

    ‘never’

    [‘on test start’, ‘never’]


    Display values:

    • ‘on test start’: ‘On start of test’

    • ‘never’: ‘Never’

    string

    Resets the model at each package start if set to “On start of test”. This will reload the model to the platform and reinitialize the XIL MA port. Measurement and online calibration are temporarily stopped. Automatic reset requires automatic “Download always” to be enabled in property “Always reload model”.

    Recording task

    ‘Tool-Default’

    string

    Recording acquisition rate to use as fallback, if there is no given acquisition rate for the test value (’*’ and ‘?’ may be used as wildcards).

    “Tool-Default” uses the first available acquisition rate.

    Use common recorder

    ☐

    bool

    Defines whether signals of this port should be recorded together with those of other ports of this tool. This guarantees a common time base and creates a single recording file. Otherwise a separate recording file is created.

    Jobs đŸ›ˆÂ¶

    ExecuteTargetScript¶

    Loads a target script to the target system and executes it. The execution time is limited by the tool’s setting “Timeout for tool call”. If you specify input or ouput parameters, you must create an XML configuration file with the same file name as the script. For example, “scripts/rtt_script.py” expects the configuration file “scripts/rtt_script.xml”. You can find sample configurations in the dSpace XIL examples.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    inputParameters

    {}

    object

    Input parameters for Target Script as dictionary {“parameterName”: “parameterValue”}. Only primitive data types are supported.

    outputParameterNames

    []

    object

    List of output parameters to be returned. These are read from the target script after execution. To be entered as a list of strings. Only primitive data types are supported.

    targetScriptPath

    uri

    Absolute or relative path to target script on this machine. Relative paths are resolved relative to the workspace directory.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    Values of output parameters as dictionary {“outputParameter”: “valueAfterExecution”}. The target script parameters to be returned need to be specified before execution with the respective job parameter.

    GetStimulationState¶

    GetStatus of stimulation

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    InstanceIdentifier

    string

    Instance identifier of the stimulus of which to query the state.

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    return

    string

    ‘configuration’, ‘ready’, ‘running’, ‘paused’, ‘finished’, ‘stopped’, ‘not started’ or ‘unkown: <SignalGeneratorState>’

    ReadVariable¶

    Read model variables

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    VariablePath

    uri

    full model path

    WriteVariable¶

    Write model variables

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Value

    string

    VariablePath

    uri

    full model path

    2025-12-05
    Previous
    Port SERVICEACCESS - SERVICE_MANAGER 🛈
    Next
    Port MODELACCESS - NO_HILAPI 🛈