Port MODELACCESS - ETHOPTO64OUT πΒΆ
Model access
StimulationΒΆ
This port has no stimulus capabilities.
Supported execution modesΒΆ
See also: Temporal behaviour: Real time and simulation time modes
Preferred time source/mode: Real-time
- Real-time:
To use real-time mode, the Test configuration in the Execution tab must be configured as the source βreal timeβ.
Info
The following modes are not supported: Stepwise simulation time, Continuous simulation time
Properties πΒΆ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Device number |
0 |
int |
Describes the device number of the card to be opened. |
||
Support for online model querying |
β |
bool |
(De-)Activates the interface for online querying of model information by the test configuration |
||
Activate timeout: |
β |
bool |
Activates the timer that turns off the outputs after a certain timeout. |
||
Timeout time |
β5.6sβ |
[β0.35sβ, β0.7sβ, β1.4sβ, β2.8sβ, β5.6sβ, β11.2sβ, β22.4sβ, β44.7sβ] |
string |