Skip to content
logo
ecu.test 2025.3 Help
Port BUSACCESS - CAPTURE-CAN(-FD) πŸ›ˆ
  • English
  • Deutsch
Initializing search
    • Getting Started
    • Overview
    • ecu.test Main program
    • Further included programs
    • Tools
      • A&D: iTest
      • ASAM: ACI
      • ASAM: iLinkRT
      • ASAM: XIL
      • ASAP: STEP
      • ATI: VISION
      • AVL: LYNX
      • AVL: PUMA
      • Basler: pylon
      • Beckhoff: TwinCAT
      • Digiteq: FG4 MultiBox
      • Digiteq: MGB
      • dSPACE: AURELION
      • dSPACE: ControlDesk
      • dSPACE: ModelDesk
      • dSPACE: MotionDesk
      • dSPACE: RTMaps
      • dSPACE: XIL API
      • EA: UTA 12
      • EMVA: GenICam
      • ESI: SimulationX
      • ETAS: BOA
      • ETAS: COSYM-SIL
      • ETAS: INCA
      • ETAS: LABCAR-PINCONTROL
      • FEP
      • FEP3
      • FEV: MorphΓ©e
      • froglogic: Squish
      • Google: ADB
      • GΓΆpel: Video Dragon
      • Hexagon: VTD
      • HMS: ACT - Restbussimulation
      • HMS: Legacy Bus Interfaces (VCI V2)
      • HMS: VCI V4
      • HORIBA FuelCon: TestWork
      • IDS: uEye
      • IPETRONIK: ETHOS
      • IPG: CarMakerHeadless
      • IPG: CarMaker|RealTimeMaker
      • JS Foundation: Appium
      • Keysight: CDS
      • Keysight: ESD
      • KS Engineers: TornadoACI
      • Lauterbach: TRACE32
      • MAGNA: BluePiraT
      • Mathworks: MATLAB & Simulink
      • Mechanical Simulation Corporation: CarSim
      • MicroNova: NovaCarts
      • Modelica Association: FMI
      • MOTEON: MTB
      • NI: LabVIEW
      • NI: VeriStand
      • NI: VISA
      • Opal-RT: RT-LAB
      • PEAK: PCAN
      • PLS: UDE
      • QUANCOM: QLIB
      • RA Consulting: DiagRA D
      • ROS2
      • SAE: PassThru
      • SFC: Selenium
      • Softing: DTS
      • Speedgoat: SimulinkRealTimeXIL
      • Synopsys: Silver
      • Synopsys: SilverXIL
      • Synopsys: Virtualizer
      • Technica: BTS
      • Technica: CM
      • The GNU Project: GDB
      • TOSUN: libTSCAN API
      • tracetronic: Ethernet
        • Ports
          • Port SERVICEACCESS - ARP πŸ›ˆ
          • Port SERVICEACCESS - ETHERNET-RAW πŸ›ˆ
          • Port SERVICEACCESS - ICMP-RAW πŸ›ˆ
          • Port SERVICEACCESS - UDP-RAW πŸ›ˆ
          • Port SERVICEACCESS - RECORDING-PCAP πŸ›ˆ
          • Port SERVICEACCESS - TCP-SERVER-PCAP-SOCKET πŸ›ˆ
          • Port SERVICEACCESS - TCP-CLIENT-PCAP-SOCKET πŸ›ˆ
          • Port SERVICEACCESS - UDP-PCAP-SOCKET πŸ›ˆ
          • Port SERVICEACCESS - SERVICE-PCAP-PASSIVE πŸ›ˆ
          • Port BUSACCESS - CAPTURE-CAN(-FD) πŸ›ˆ
            • Stimulation
            • Properties πŸ›ˆ
            • Jobs πŸ›ˆ
              • ClearFrame
              • DeregisterFrameForInbox
              • GetFirstValue
              • GetLastReceptionTimestamp
              • InitFrame
              • ReadFrame
              • ReadFrameEx
              • RegisterFrameForInbox
              • ResetFirstValue
          • Port BUSACCESS - CAPTURE-LIN πŸ›ˆ
          • Port BUSACCESS - CAPTURE-FLX πŸ›ˆ
          • Port LOGGING - DLT-VERBOSE πŸ›ˆ
          • Port BUSACCESS - SOCKETADAPTOR πŸ›ˆ
          • Port SERVICEACCESS - IPSEC πŸ›ˆ
          • Port BUSACCESS - IEEE1722-CAN(-FD) πŸ›ˆ
          • Port SERVICEACCESS - MACSEC πŸ›ˆ
          • Port SERVICEACCESS - SERVICE πŸ›ˆ
          • Port SERVICEACCESS - TCP-SERVER-SOCKET πŸ›ˆ
          • Port SERVICEACCESS - TCP-CLIENT-SOCKET πŸ›ˆ
          • Port SERVICEACCESS - UDP-SOCKET πŸ›ˆ
          • Port SERVICEACCESS - TLS πŸ›ˆ
          • Port DIAGNOSTICS - DOSOAD-SOCKET πŸ›ˆ
          • Port DIAGNOSTICS - DOIP-SOCKET πŸ›ˆ
          • Port DIAGNOSTICS - DOIP-PCAP πŸ›ˆ
          • Port DIAGNOSTICS - IEEE1722-J1939 πŸ›ˆ
          • Port APPLICATION - XCP-ETH πŸ›ˆ
          • Port APPLICATION - XCP-PCAP πŸ›ˆ
          • Port MODELACCESS - CAPTURE-ANALOG πŸ›ˆ
          • Port DIAGNOSTICS - SOVD-SOCKET πŸ›ˆ
      • tracetronic: Multimedia
      • tracetronic: RemoteCommand
      • tracetronic: RemoteCommandLinux
      • tracetronic: Serial interface
      • tracetronic: SocketCAN
      • tracetronic: SSH MultiConnect
      • tracetronic: ZeroMQ
      • TTTech: TTXConnexion
      • Typhoon HIL: THCC
      • Vector: CANape
      • Vector: CANoe / CANalyzer
      • Vector: DYNA4
      • Vector: SIL Kit
      • Vector: XL API
      • Vehinfo: LABCAR
      • ViGEM: CCA
      • VW: ODIS
      • X2E: Xoraya
      • Tools with stimulus support
    • Test execution
    • Trace analysis
    • Workspace
    • Handling
    • Test management
    • test.guide
    • Extensions
    • Specific Tutorials
    • API references
    • System requirements
    • ecu.test on Linux
    • ecu.test code
    • ecu.test agent
    • ecu.test lab
    • Stimulation
    • Properties πŸ›ˆ
    • Jobs πŸ›ˆ
      • ClearFrame
      • DeregisterFrameForInbox
      • GetFirstValue
      • GetLastReceptionTimestamp
      • InitFrame
      • ReadFrame
      • ReadFrameEx
      • RegisterFrameForInbox
      • ResetFirstValue

    Port BUSACCESS - CAPTURE-CAN(-FD) πŸ›ˆΒΆ

    Capture access to CAN FD

    This port is only available if Npcap is installed.

    StimulationΒΆ

    This port supports all features described in Stimulation control.

    Properties πŸ›ˆΒΆ

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    Network interface card

    string

    Used network interface card

    Logger protocol

    PLP/TECMP

    [PLP/TECMP, ASAM CMP]

    string

    Which logger protocol is used.

    Probe ID / Device ID

    Logger protocol: β€˜PLP/TECMP’

    0

    int

    Identifier of the probe / device

    Bus Spec ID / Interface ID

    Logger protocol: β€˜PLP/TECMP’

    0

    int

    Identifier of the bus specification / interface

    Device-ID and Stream-ID

    Logger protocol: β€˜ASAM CMP’

    β€˜(0,0)’

    string

    Tuple consisting of device ID and stream ID, e.g.: (0,0)

    Interface-ID

    Logger protocol: β€˜ASAM CMP’

    0

    int

    Identifier of the interface

    Mode

    Standard

    [Standard, Extended, All]

    string

    Addressing mode (Standard = 11bit, Extended = 29bit)

    Receive error frames

    ☐

    bool

    Receive error frames

    Trace format

    ASC

    [ASC, MDF4, PCAPNG]

    string

    Default file format for bus recordings. PCAPNG for bus is not supported by trace analysis

    Bus-DB

    string

    J1939 mode

    Mode: β€˜Extended’

    ☐

    bool

    Ignore the three most significant bits of the CAN-ID and J1939 source address. Extract signals from J1939-TP and ISOBus-ETP.

    Jobs πŸ›ˆΒΆ

    ClearFrameΒΆ

    Erases the receiving buffer of given frame

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameId

    int

    Frame ID

    isExtended

    None

    [False, True]

    bool

    Address format: True for 29 bit, False for 11 bit, None uses the setting β€œMode” from the test bench configuration

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    ByteStream

    ByteStream

    DeregisterFrameForInboxΒΆ

    Deregisters a frame that is streamed to the inbox

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameId

    int

    Frame ID

    Inbox

    object

    Existing inbox

    isExtended

    None

    [False, True]

    bool

    Address format: True for 29 bit, False for 11 bit, None uses the setting β€œMode” from the test bench configuration

    GetFirstValueΒΆ

    Returns the first value of the signal received since the test case started.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameName

    string

    Frame name

    NodeName

    string

    Name of the electronic control unit

    RawValue

    False

    [False, True]

    bool

    If β€˜True’, the Raw value is returned.

    Reset

    False

    [False, True]

    bool

    If β€˜True’ the first received value will be deleted after it has been read

    SignalName

    string

    Signal name

    GetLastReceptionTimestampΒΆ

    Get the last reception timestamp in seconds

    InitFrameΒΆ

    Registers the message ID for later use, e.g. ReadFrame

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameId

    int

    Frame ID

    isExtended

    None

    [False, True]

    bool

    Address format: True for 29 bit, False for 11 bit, None uses the setting β€œMode” from the test bench configuration

    ReadFrameΒΆ

    Reads the given frame ID (use InitCanFrame before!)

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    doDelete

    False

    [False, True]

    bool

    Deletes the Frame after reading if β€œTrue”

    FrameId

    int

    Frame ID

    isExtended

    None

    [False, True]

    bool

    Address format: True for 29 bit, False for 11 bit, None uses the setting β€œMode” from the test bench configuration

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    ByteStream

    ByteStream

    ReadFrameExΒΆ

    Reads the given frame ID (use InitCanFrame before!)

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    doDelete

    False

    [False, True]

    bool

    Deletes the Frame after reading if β€œTrue”

    FrameId

    int

    Frame ID

    isExtended

    None

    [False, True]

    bool

    Address format: True for 29 bit, False for 11 bit, None uses the setting β€œMode” from the test bench configuration

    Return value

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    result

    object

    CanFrame

    RegisterFrameForInboxΒΆ

    Registers a frame to be streamed to an inbox.

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameId

    int

    Frame ID

    Inbox

    object

    Existing inbox

    isExtended

    None

    [False, True]

    bool

    Address format: True for 29 bit, False for 11 bit, None uses the setting β€œMode” from the test bench configuration

    saveAsCanFrame

    False

    [False, True]

    bool

    If True, the frame is saved as a CanFrame object, else as a ByteStream

    ResetFirstValueΒΆ

    Erases the first received value of the given signal

    Parameterization

    Parameter

    Name

    Available if

    Default value

    Valid values

    Type

    Description

    FrameName

    string

    Frame name

    NodeName

    string

    Name of the electronic control unit

    SignalName

    string

    Signal name

    2025-12-05
    Previous
    Port SERVICEACCESS - SERVICE-PCAP-PASSIVE πŸ›ˆ
    Next
    Port BUSACCESS - CAPTURE-LIN πŸ›ˆ
    © Copyright 2025, tracetronic GmbH.
    Created using Sphinx 8.2.3. and Sphinx-Immaterial
    Logo of tracetronic GmbH
    legal notice privacy policy