Port LOGGING - DLT-VERBOSE ๐ยถ
Access to DLT verbose messages
This port is only available if Npcap is installed.
Stimulationยถ
This port has no stimulus capabilities.
Properties ๐ยถ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Active mode |
โ |
bool |
When this option is selected, ecu.test actively connects to the site. If the setting is not selected, ecu.test does not establish a Connection itself. Rather, only data addressed to another tool is read (passive mode). |
||
DLT TCP auto reconnect timeout [sec] |
Active mode: โTrueโ |
float |
ecu.test will automatically restart the DLT TCP connection if no new DLT messages arrive within the configured number of seconds. An empty value for the timeout switches the auto reconnect feature off. |
||
Pre-recording circular buffer |
Active mode: โTrueโ |
0 |
int |
Since the recording gets started only a short time after the connection to the ecu is established, even with auto-start/stop, messages sent by the ECU only once immediately after the connection is made, can be lost. With this setting, the recording can be โextended forwardโ by the specified number of messages, in order to include these initial messages. |
|
Network interface card |
Active mode: โFalseโ |
[โโ] |
string |
Used network interface card |
|
VLAN settings |
Active mode: โFalseโ |
โno taggingโ |
[โno taggingโ, โsingle taggingโ] |
string |
Used VLAN setting |
VLAN-VID |
Active mode: โFalseโ |
1 |
int |
Integer, only used if VLAN tagging is enabled |
|
Logger protocol |
Active mode: โFalseโ |
[, PLP/TECMP, ASAM CMP] |
string |
Use a logger protocol such as ASAM CMP. The port can then only be used for reading. Ethernet frames contained in the logger messages are extracted and the filter in BPF format (if specified) is applied to these frames. |
|
Device-IDs / Probe-IDs |
Active mode: โFalseโ ยป Logger protocol: โPLP/TECMPโ |
string |
Identifiers of the devices / probes: empty if no filtering based on device / probe IDs is required; several can be separated by commas. |
||
Device and Stream IDs |
Active mode: โFalseโ ยป Logger protocol: โASAM CMPโ |
string |
Identifiers of the devices and streams as a list of tuples, each consisting of device ID and stream ID, e.g.: (1,2),(3,4). Leave empty if no filtering based on device and stream ID is needed. |
||
Interface-IDs / Bus-Spec-IDs |
Active mode: โFalseโ ยป Logger protocol: โPLP/TECMPโ |
string |
Identifiers of the interfaces / bus specs: empty if no filtering based on bus interface / spec IDs is required; several can be separated by commas. |
||
Interface IDs |
Active mode: โFalseโ ยป Logger protocol: โASAM CMPโ |
string |
Identifiers of the interfaces: empty if no filtering based on interface IDs is required; several can be separated by commas. |
Jobs ๐ยถ
Reconnectยถ
In Active Mode, reconnects and clears the message buffers.
Parameterization
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
result |
False |
[False, True] |
bool |