Port BUSACCESS - CAPTURE-FLX πΒΆ
Capture access to FlexRay
This port is only available if Npcap is installed.
StimulationΒΆ
This port supports all features described in Stimulation control.
Properties πΒΆ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Network interface card |
string |
Used network interface card |
|||
Logger protocol |
PLP/TECMP |
[PLP/TECMP, ASAM CMP] |
string |
Which logger protocol is used. |
|
Probe ID / Device ID |
Logger protocol: βPLP/TECMPβ |
0 |
int |
Identifier of the probe / device |
|
Bus Spec ID / Interface ID |
Logger protocol: βPLP/TECMPβ |
0 |
int |
Identifier of the bus specification / interface |
|
Device-ID and Stream-ID |
Logger protocol: βASAM CMPβ |
β(0,0)β |
string |
Tuple consisting of device ID and stream ID, e.g.: (0,0) |
|
Interface-ID |
Logger protocol: βASAM CMPβ |
0 |
int |
Identifier of the interface |
|
Bus-DB |
string |
||||
Logging of events |
β |
bool |
The Events SCE, SE and EE will be written to the ASC file during recording |
||
Null frames |
β |
bool |
Null frames will be logged only if βTrueβ |
Jobs πΒΆ
ClearFrameΒΆ
Erases the receiving buffer of given frame
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Channel |
βAβ |
[βAβ, βBβ, β*β] |
string |
FlexRay Channel (A, B or *) |
|
CycleRepetition |
int |
Cycle repetition |
|||
SlotId |
int |
Frame ID |
|||
StartCycle |
int |
Start cycle |
DeregisterFrameForInboxΒΆ
Ungeristers a frame that is being streamed to an inbox
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Channel |
βAβ |
[βAβ, βBβ, β*β] |
string |
FlexRay Channel (A, B or *) |
|
CycleRepetition |
int |
Cycle repetition |
|||
Inbox |
object |
Existing inbox |
|||
SlotId |
int |
Frame ID |
|||
StartCycle |
int |
StartCycle (cycle offset) |
GetFirstValueΒΆ
Reads the first received value of the given signal
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameName |
string |
Frame name |
|||
NodeName |
string |
Name of the electronic control unit |
|||
RawValue |
False |
[False, True] |
bool |
If βTrueβ, the Raw value is returned. |
|
reset |
False |
[False, True] |
bool |
If βTrueβ the first received value will be deleted after it has been read |
|
SignalName |
string |
Signal name |
InitFrameΒΆ
Initializes the given frame
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Channel |
βAβ |
[βAβ, βBβ, β*β] |
string |
FlexRay Channel (A, B or *) |
|
CycleRepetition |
int |
Cycle repetition |
|||
DataLength |
int |
Length in words |
|||
SlotId |
int |
Frame ID |
|||
StartCycle |
int |
StartCycle (cycle offset) |
ReadFrameΒΆ
Reads the given frame (use InitFrame before!)
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Channel |
βAβ |
[βAβ, βBβ, β*β] |
string |
FlexRay Channel (A, B or *) |
|
CycleRepetition |
int |
Cycle repetition |
|||
doDelete |
False |
[False, True] |
bool |
Deletes the Frame after reading if βTrueβ |
|
SlotId |
int |
Frame ID |
|||
StartCycle |
int |
StartCycle (cycle offset) |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
result |
ByteStream |
ByteStream |
ReadFrameExΒΆ
Reads the given frame (use InitFrame before!)
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Channel |
βAβ |
[βAβ, βBβ, β*β] |
string |
FlexRay Channel (A, B or *) |
|
CycleRepetition |
int |
Cycle repetition |
|||
doDelete |
False |
[False, True] |
bool |
Deletes the Frame after reading if βTrueβ |
|
SlotId |
int |
Frame ID |
|||
StartCycle |
int |
StartCycle (cycle offset) |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
result |
object |
FlexRayFrame |
RegisterFrameForInboxΒΆ
Registers a frame to be streamed to an inbox.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Channel |
βAβ |
[βAβ, βBβ, β*β] |
string |
FlexRay Channel (A, B or *) |
|
CycleRepetition |
int |
Cycle repetition |
|||
Inbox |
object |
Existing inbox |
|||
saveAsFlxFrame |
False |
[False, True] |
bool |
If True, the frame is saved as a FlexRayFrame object, else as a ByteStream |
|
SlotId |
int |
Frame ID |
|||
StartCycle |
int |
StartCycle (cycle offset) |
ResetFirstValueΒΆ
Erases the first received value of the given signal
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameName |
string |
Frame name |
|||
NodeName |
string |
Name of the electronic control unit |
|||
SignalName |
string |
Signal name |
SetFlowControlCTSΒΆ
Activates to always send a Flow Control βContinueToSendβ message in response to a segmented request. Also new values can be assigned to the internal parameters BlockSize, MNPC and SCexp.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
BlockSize |
int |
Block size in bytes; maximum number of bytes that may be transmitted in the following consecutive frames before the sender has to wait for another flow control frame. - Integer If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept. |
|||
MNPC |
int |
MNPC specifies how many consecutive frames the receiver can process within one FlexRay cycle. With MNPC set to 0 the sender can utilize the maximum possible band width. - Integer If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept. |
|||
SCexp |
int |
SC defines the minimum distance in cycles until the sender is allowed to send the next consecutive frame. SC = 2^SCexp - 1 - Integer If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept. |
|||
SessionId |
object |
Handle of the diagnostic session. This can be either the name of the SUT specified in the TCF, the handle returned by the OpenDiagSession job or None (can only be used if there is one SUT specified). |
SetFlowControlWaitΒΆ
Activates to always send a Flow Control βWaitβ messages in response to a segmented request. Note: While activated no segmented message can be received. Use the Job SetFlowControlCTS to reset this behaviour.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
SessionId |
object |
Handle of the diagnostic session. This can be either the name of the SUT specified in the TCF, the handle returned by the OpenDiagSession job or None (can only be used if there is one SUT specified). |
|||
WaitTimeInterval |
0 |
int |
Wait time interval in ms. If set to 0, Flow Control βWaitβ messages are only sent once, to respond to a segmented request. If set to a value greater than 0, Flow Control βWaitβ messages will be sent periodically with the given interval in between. |
SwitchBusStateΒΆ
Switches the FlexRay controller on or off.
Caution: switching the controller on will reset the ASC timestamps. Recording during the stop and start of the controller may result in an ASC file which violates the monotony of timestamps.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
State |
βOffβ |
[βOffβ, βOnβ] |
string |