Port MODELACCESS - DEFAULT πΒΆ
Model access
StimulationΒΆ
This port has no stimulus capabilities.
Supported execution modesΒΆ
See also: Temporal behaviour: Real time and simulation time modes
Preferred time source/mode: Continuous simulation time
- Real-time:
To use real-time mode, the Test configuration in the Execution tab must be configured as the source βreal timeβ.
- Continuous simulation time:
To use the continuous simulation mode, the port in the Test configuration in the Execution tab must be selected and the mode set to βcontinuousβ.
Info
The following modes are not supported: Stepwise simulation time
Properties πΒΆ
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Time resolution [ms] |
10 |
int |
Resolution of the simulation time in milliseconds (simulation step size). |
||
Maximum ratio of model time to system time |
1.0 |
float |
If the model time in the SIL Kit is significantly faster than the real time, the processing speed of ecu.test may not be sufficient to correctly check or comply with time conditions. If the ratio set here is exceeded, ecu.test delays the simulation accordingly. |
Jobs πΒΆ
GetSimulationTimeΒΆ
Determines the current simulation time in the Vector SIL kit if the model port was selected as time source in the TCF
Parameterization
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
result |
float |
Simulation time in seconds |