Port IMAGE - DEFAULT

Default port for interaction with Digiteq FG4 MultiBox frame grabbers

Stimulation

This port has no stimulus capabilities.

Specifics

Configuration of the video inputs

ecu.test currently does not support configuration of the video inputs in the test bench configuration, so this must be done manually in the FG4 MultiBox web interface under the “Video Inputs” menu item. In order to find the configured video input more quickly, a custom name can be assigned to the input under “Custom Name”, which is also displayed in the test bench configuration.

The live preview, the image read test step and the signal recording are performned via the TCP video stream that can be configured under “Sinks”. The optional internal memory of the FG4 MultiBox is currently not accessed. If the stream is not activated at the start of the configuration, it will be automatically activated and remains active even after the configuration is stopped.

Name

Available if

Default value

Valid values

Type

Description

Device

[ONLINE]

string

The device name and the optional custom name of the available video inputs are listed. The selected device is identified by its device name when the port is started.

Live preview

☐

bool

Streams a live preview on the configured network port. The live stream is available under the toolhost’s IP address and the configured port, e.g. for a local tool connection: http://127.0.0.1:<port>

Open preview window

Live preview

☑

bool

Opens a preview window upon loading the configuration. This window displays the current output of the image source as a livestream and will remain open as long as the test configuration is active.

Port

Live preview

‘<auto>’

string

The network port that will be used for live streaming. Every live stream needs an unique port if live streaming is enabled for multiple video sources. If the value is set to <auto> a free network port will be defined by the system.

Show text overlay in video recordings

☐

bool

Adds a text overlay with the format “timestamp package name” in the bottom left corner of video recordings.