Port APPLICATION - GENERIC¶
Generic application access
Stimulation¶
This port has no stimulus capabilities.
Specifics¶
Over this port type, application quantities (calibration and measurement) modeled in the system can be read and manipulated.
A prerequisite is that the application quantities in the A2L file have a corresponding name in the model description of the FMU. If these model variables are located in a subpath, a static prefix can be specified in the port settings for calibration and measurement variables, which will be prepended to the application variable names.
The following operations are supported:
Calibration
Read
Write
Record
Measurement
Read
Record
Access is possible to scalars, vectors, and matrices, either as a whole or element-wise. Maps and curves are not supported.
Supported representations are PHYS and TEXT.
Properties 🛈¶
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
A2L file |
string |
A2L file used by the port |
|||
Calibration prefix |
string |
Prefix for calibration entitites including a potential dot. |
|||
Measurement prefix |
string |
Prefix for measurement entitites including a potential dot. |