Port APPLICATION - GENERIC

Generic application access

Stimulation

This port has no stimulus capabilities.

Specifics

Over this port type, application quantities (calibration and measurement) modeled in the system can be read and manipulated.

A prerequisite is that the application quantities in the A2L file have a corresponding name in the model description of the FMU. If these model variables are located in a subpath, a static prefix can be specified in the port settings for calibration and measurement variables, which will be prepended to the application variable names.

The following operations are supported:

Calibration

  • Read

  • Write

  • Record

Measurement

  • Read

  • Record

Access is possible to scalars, vectors, and matrices, either as a whole or element-wise. Maps and curves are not supported.

Supported representations are PHYS and TEXT.

Name

Available if

Default value

Valid values

Type

Description

A2L file

string

A2L file used by the port

Calibration prefix

string

Prefix for calibration entitites including a potential dot.

Measurement prefix

string

Prefix for measurement entitites including a potential dot.