Port APPLICATION - Standard

Stimulation

This port has no stimulus capabilities.

Name

Available if

Default value

Valid values

Type

Description

Device name

‘CCPsim’

string

Name of access interface

Device channel

1

int

Name of access interface

Devices

CCP

[CCP, XCP]

string

Driver of access interface

Network name

Devices: ‘Ethernet’

string

Name of ethernet network (for network based access mode). Leave empty for channel based access mode.

Check access

☑

bool

Check device access after tool startup.

A2L file

uri

A2L file used by the port

Hex file

uri

Hex file used by the port

Mirror cache

Ignore

[Ignore, Disable, Enable]

uri

Enable or diable the mirror cache after initialisation of the device. Only has an effect on devices that are created by ecu.test.

Automatic recording

☐

bool

If this option is active, all signals used in the test case are automatically registered for recording.

Default acquisition rate

‘Tool-Default’

string

Declaration of measurement acquisition rate used as alternative in case no acquisition rate is set in the test step (’*’ and ‘?’ can be used as wildcard). “Tool-Default” activates the use of the standard acquisition rate of the tool

Procrastination for validation

-1

int

Defines the procrastination used for validating a written calibration value. If set to “-1” no validation will be performed.

Validation tolerance for calibration

3

float

Defines the tolerance used for validating a written calibration value. The value must be given in percent.

Force upload of calibration values

☐

bool

From CANape 12 SP8: Forces uploading calibration values. This is necessary when a calibration value is also written by the control unit software.

Do not transfer A2L and HEX file to CANape

☐

bool

This setting allows to skip the time for copying and reading the A2L and HEX files into CANape, if a CANape project which already includes the correct file is used.

DownloadWorkbase

Download WP/RP from data set to control unit

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

force

False

[False, True]

bool

GetAquisitionRates

Provides a list of all acquisition rates

IsDeviceRunning

Returns if the ECU is online.

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

[False, True]

bool

StartDevice

Establishes the connection from CANape to the ECU

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

download

False

[False, True]

bool

Activates the automatic download during “GoOnline”.

timeout

2000

float

Timeout for the start in ms.

Return value

Name

Available if

Default value

Valid values

Type

Description

result

[False, True]

bool

StopDevice

Disconnects the ECU from CANape

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

timeout

2000

float

Timeout for the stop in ms.

Return value

Name

Available if

Default value

Valid values

Type

Description

result

[False, True]

bool