Port DIAGNOSTICS - J1939¶
PEAK-HW access to J1939 via CAN. Component of the Add-on ecu.test diagnostics
Stimulation¶
This port has no stimulus capabilities.
Properties 🛈¶
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Channel number |
‘1’ |
string |
Selection of channel number if there is more than one controller of same type. |
||
Bit rate |
‘500KB’ |
[‘10KB’, ‘20KB’, ‘50KB’, ‘83.333KB’, ‘100KB’, ‘125KB’, ‘250KB’, ‘500KB’, ‘666.667KB’, ‘800KB’, ‘1000KB’] |
string |
Bit rate |
|
J1939 Tester Name |
‘00:00:20:04:00:81:00:20’ |
string |
Byte sequence for the Address Claim name (separated by a colon) |
||
J1939 Tester Source Address |
123 |
int |
Source address used for the J1939 Address Claim (must be > 0). |
||
J1939 TP Priority |
6 |
int |
Priority of the control messages used by the J1939 Connection Mode Datatransfer Protocol (value from 0 to 7). |
||
Transmission confirmation |
☐ |
bool |
Activates acknowledged sending. Bus-Write test steps and Send tool jobs block until the message was successfully transferred on the bus or the confirm timeout expired. |
||
Timeout for transmission confirmation |
1000 |
int |
Period in miliseconds in which a message has to be sent successfully. Otherwise an error is created. (must not be larger than 64535ms). Is only used in active confirm mode. |
Jobs 🛈¶
ClearDTC¶
Deletes all previously active (DM3) and active (DM11) error codes
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
DestinationAddress |
string |
Numeric Id or TLA of the receiver. Use 0xff for broadcast. |
|||
DTC |
‘Previously Active’ |
[‘Active’, ‘Previously Active’] |
string |
Type of DTC |
CloseJ1939MemoryAccessSession¶
Closes the diagnostic session
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
DestinationAddress |
string |
Numerical ID or TLA of the receiver. |
DTCRequest¶
Request of active (DM1) and previously active (DM2) error codes
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
DestinationAddress |
string |
Numeric Id or TLA of the receiver. Use 0xff for broadcast. |
|||
DTC |
‘Active’ |
[‘Active’, ‘Previously Active’] |
string |
Type of DTC |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Return |
object |
Received J1939DTCList object. |
GenericPGNSendReceive¶
Sends a user-specific J1939 message and expects the response message with the specified parameters
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
ReceivePayloadFilterMask |
ByteStream |
Mask for the Byte to be checked (ByteStream) |
|||
ReceivePayloadFilterValue |
ByteStream |
Byte values which the payload of the message must accept (ByteStream) |
|||
ReceivePduFormat |
0 |
int |
First byte of the received PGN |
||
ReceivePduSpecific |
0 |
int |
Second byte of the received PGN |
||
SendPayload |
ByteStream() |
ByteStream |
Payload for sending, if the ByteStream is empty, it is only received. |
||
SendPduFormat |
0 |
int |
First byte of the PGN to be sent |
||
SendPduSpecific |
0 |
int |
Second byte of the PGN to be sent |
||
SendPriority |
0 |
int |
Priority of the message to be sent |
||
Timeout |
1 |
int |
Time in seconds to wait for answers |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Return |
object |
List of the received J1939Message objects. |
GetAvailableTLAs¶
Returns a dictionary of all active participants with their source address and their TLA (Three Letter Acronym)
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Return |
object |
Dict {sourceAddress: TLA} |
MemoryAccessRequest¶
Sends a memory access request (DM14) and provides the corresponding answers (DM15, DM16)
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Command |
‘Read’ |
[‘Erase’, ‘Read’, ‘Write’, ‘Status Request’, ‘Operation Completed’, ‘Operation Failed’, ‘Boot Load’, ‘EDCP Generation’] |
string |
Type of memory access |
|
DestinationAddress |
string |
Numerical ID or TLA of the receiver. |
|||
Key |
65535 |
int |
Default: No Key (0xFFFF) |
||
Length |
0 |
int |
Depending on Pointer Type (PT) the length of the addressed memory in bytes (PT = 0) or the number of objects (PT = 1) |
||
Pointer |
0 |
int |
|||
PointerExtension |
0 |
int |
|||
PointerType |
‘Direct Spatial Addressing’ |
[‘Direct Memory Addressing’, ‘Direct Spatial Addressing’] |
string |
||
WriteData |
ByteStream() |
ByteStream |
Write data for “Write” command |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Return |
object |
List of the received J1939Message objects. |
OpenJ1939MemoryAccessSession¶
Opens a J1939 diagnostic session (memory access) and keeps it open, by sending the specified message content cyclically via DM14 every [timeout] ms.
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
DestinationAddress |
string |
Numerical ID or TLA of the receiver. |
|||
Key |
65535 |
int |
Default: No Key (0xFFFF) |
||
Length |
0 |
int |
Depending on Pointer Type (PT) the length of the addressed memory in bytes (PT = 0) or the number of objects (PT = 1) |
||
Pointer |
0 |
int |
|||
PointerExtension |
0 |
int |
|||
PointerType |
‘Direct Spatial Addressing’ |
[‘Direct Memory Addressing’, ‘Direct Spatial Addressing’] |
string |
||
Timeout |
80 |
int |
Time in ms in which a message is sent to the test object to maintain diagnostic access |
Receive¶
Returns the last received message with the specified PduFormat, PduSpecific and if required the SourceAddress
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
PduFormat |
int |
||||
PduSpecific |
int |
||||
SourceAddress |
int |
Sender ID or the filtered TLA (empty if no filter) |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Return |
object |
Received J1939Message object. |
Send¶
Sends a custom J1939 message
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Payload |
ByteStream() |
ByteStream |
Payload for the request. |
||
PduFormat |
int |
||||
PduSpecific |
int |
||||
Priority |
int |
StandardPGNRequestResponse¶
Sends a standard PGN request and returns the response
This job is part of the Add-on ecu.test diagnostics.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
DestinationAddress |
string |
Numeric Id or TLA of the receiver. Use 0xff for broadcast. |
|||
Payload |
ByteStream() |
ByteStream |
Payload for the request. |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Return |
object |