Port BUSACCESS - MODEL BASED¶
The port provides bus access via model variables. To map bus paths to model paths, ecu.test uses a user defined BusToModelPathResolver. Depending on the signal type and variable usage, ecu.test calls one of the methods of this resolver.
Stimulation¶
Stimulation of bus signals is performed via the model access and is only possible if this also supports stimulation. The restrictions/comments of the model access also apply to the model based bus access.
Restrictions:
Stimulus input signals are not supported.
Trace files being referenced by a DataFileSegment in an STI file are not converted automatically by ecu.test.
It is up to the user to check whether the trace format being used is supported by the tool.
Properties 🛈¶
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Model port |
string |
Port ID (e.g. “MDL01”) of the model port via which the model access is to be performed. This property can remain empty if there is exactly one model port. |
|||
Bus database |
string |
Path to a bus database or empty if the path should be taken from the test configuration. If a path is entered, it must be a path that is available on the tool’s system. The bus database is not transferred automatically in this case. |
|||
Bus identifier |
string |
Logical name of the bus system. |
|||
Raw to phys conversion behavior |
‘error’ |
[‘error’, ‘identical’, ‘first’, ‘firstOrIdentical’] Display values:
|
string |
Behavior for conversions of raw values in domains without a specified conversion rule. This option should be set according to how the model represents signal values that have no physical representation. By default, such values are not allowed. The option “identical” treats raw values directly as phys values. The “first conversion function” applies the first defined conversion function on the raw value even if it is not defined for that value. The “first conversion function or identical” option uses a first conversion function, if available, or the raw value if no conversion function is defined. |
Jobs 🛈¶
ResetPDUActivation¶
Reverts the specification of the PDU activation state.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
pduPath |
string |
Bus path of the respective PDU. |
ResetPDUTiming¶
Reverts the specification of a PDU cycle time.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
pduPath |
string |
Bus path of the respective PDU. |