Port APPLICATION¶
Stimulation¶
This port has no stimulus capabilities.
Properties đ¶
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Platform name |
âXCPâ |
string |
Name of the platform as specified in the Experiment. Alternatively the platform name in the ControlDesk Platform Management can be used. |
||
Standard acquisition rate |
â5msâ |
string |
Declaration of measurement acquisition rate used as alternative in case no acquisition rate is set in the test step (â*â and â?â can be used as wildcard). âTool-Defaultâ activates the use of the standard acquisition rate of the tool |
||
Recording task |
âTool-Defaultâ |
string |
Recording acquisition rate to use as fallback, if there is no given acquisition rate for the test value (â*â and â?â may be used as wildcards). âTool-Defaultâ uses the first available acquisition rate. |
||
Use common recorder |
â |
bool |
Defines whether signals of this port should be recorded together with those of other ports of this tool. This guarantees a common time base and creates a single recording file. Otherwise a separate recording file is created. |
Jobs đ¶
ActivateDCMFileAsWorkingPage¶
Uploads a DCM or CDFX file on the ControlDesk host and activates it as working page.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
DCMFile |
string |
Absolute path of the DCM or CDFX file to be loaded in ControlDesk as active WorkingPage. |
ImportDCMFile¶
Loads a DCM or CDFX file on the ControlDesk host and imports it as a new data set.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
BehaviorIfFileExists |
âerrorâ |
[ânothingâ, âreplaceâ, âerrorâ] Display values:
|
string |
If the file already exists as a data set in ControlDesk NG this job does either nothing, replaces the data set or throws an error. |
|
DCMFile |
string |
Absolute path of the DCM or CDFX file that should be imported in ControlDesk. |
|||
DownloadOnCalibStart |
â |
bool |
If this property is set to âTrueâ, the option âDownload on Calibration Startâ will be set for the imported data set. |
||
WriteToWorkingDataSet |
â |
bool |
If set âTrueâ the method âWriteToWorkingDataSetâ will be called for the imported File. |
RemoveDataSet¶
Removes DataSet(s) from the current project.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
DataSetPattern |
string |
Filename of DataSet. (â*â and â?â can be used as wildcards) If expression matches multiple entries, all will be removed |
|||
removeFromDisk |
â |
bool |
If this property is âTrueâ, the file will also be deleted from the hard disk. Else it is only removed from the project. |