Port MODELACCESS

Stimulation

This port has no stimulus capabilities.

Supported execution modes

See also: Specifics of time modes

Preferred time source/mode: Real-time

Real-time:

To use real-time mode, the Test configuration in the Execution tab must be configured as the source ‘real time’.

Info

The following modes are not supported: Stepwise simulation time, Continuous simulation time

Name

Available if

Default value

Valid values

Type

Description

Serial number

[ONLINE]

string

Serial number of the BT

Channel number

1

[ONLINE]

int

Channel number (from the BT manager)

ActivateManualMode

Sets the channel into manual mode

DeactivateManualMode

Deactivates manual mode for this channel

GetActualChannelMeasurement

Queries the current measurement values of the channel

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

object

Dictionary with the current measurement values

GetAllActualMeasurementNames

Queries the names of the measurements of the channel

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

object

List of measurement names

GetBoundedChannelReport

Queries the report currently bound to the channel

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

string

Path to the report

GetChannelErrorCode

Queries the channel’s error code.

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

object

Error code of the channel

GetChannelState

Queries the channel’s status.

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

object

Status of the channel

GetExtIOInputByName

Returns the value of the external input

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

inputName

string

Name of the input

Return value

Name

Available if

Default value

Valid values

Type

Description

result

float

GetOneActualChannelMeasurement

Queries a current measurement value from the channel

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

measurementName

int

Name of the measurement

Return value

Name

Available if

Default value

Valid values

Type

Description

result

float

Measurement value

GetReflectedExtIOOutputByName

Returns the reflected value of the external output

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

outputName

string

Name of the output

Return value

Name

Available if

Default value

Valid values

Type

Description

result

float

GetSystemState

Queries the system’s status.

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

object

Status of the system

GetTBGChannelErrorCode

Queries the test bench guard error code of the channel.

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

object

Error code of the test bench guard

GetTBGChannelState

Queries the test bench guard status of the channel.

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

object

Status of the test bench guard

IsChannelInManualMode

Queries whether the channel is in manual mode

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

[False, True]

bool

Pause

Pauses/Resumes the execution on the channel

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int

Reset

Resets the channel

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int

SetChannelParametrization

Sets the parameters for the test program

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

batteryPath

string

Path to battery file

parameters

object

Parameter set for the test program (as dict)

reportPath

string

Path to the report

testProgramPath

string

Path to the test program

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int

SetChannelReParametrization

Changes the parameters for the paused test program

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

parameters

object

Parameter set for the test program (as dict)

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int

SetExtIOOutputByName

Sets the value of the external output

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

outputName

string

Name of the output

value

float

Value

SetLocalChannelParametrization

Sets the parameters for the test program

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

batteryPath

string

Path to battery file

parameters

object

Parameter set for the test program (as dict)

reportPath

string

Path to the report

testProgramName

string

Name of the test program

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int

SetTBGParametrization

Sets the parameterization for the test bench guard. CAUTION: This parameterization applies to all channels!

Parameterization

Parameter

Name

Available if

Default value

Valid values

Type

Description

parametrizationPath

string

Path to the parameterization file

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int

Start

Starts the execution on the channel

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int

Stop

Stops the execution on the channel

Parameterization

Return value

Name

Available if

Default value

Valid values

Type

Description

result

int