Port BUSACCESS - CAN¶
IXXAT-HW access to CAN
Stimulation¶
This port supports all features described in Stimulation control.
Properties 🛈¶
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Channel number |
‘1’ |
string |
Selection of channel number if there is more than one controller of same type. |
||
Bit rate |
‘500KB’ |
[‘10KB’, ‘20KB’, ‘50KB’, ‘83.333KB’, ‘100KB’, ‘125KB’, ‘250KB’, ‘500KB’, ‘666.667KB’, ‘800KB’, ‘1000KB’] |
string |
Bit rate |
|
Mode |
Standard |
[Standard, Extended, All] |
string |
Addressing mode (Standard = 11bit, Extended = 29bit) |
|
Listen only |
☐ |
bool |
Controller is running in passive mode. Automatic ACK is disabled, and sending CAN frames is not possible. |
||
Receive error frames |
☐ |
bool |
Receive error frames |
||
Trace format |
ASC |
[ASC, MDF4, PCAPNG] |
string |
Default file format for bus recordings. PCAPNG for bus is not supported by trace analysis |
|
Bus-DB |
string |
||||
Placeholder value for automatic E2E calculation |
int |
Whenever this value is specified for an E2E signal (e.g. CRC), upon transmission ecu.test automatically replaces it with the correct, calculated value. The purpose of this option is to allow transmission of arbitrary fixed values (unequal to the value chosen here). Leaving this option empty completely disables the feature.For more information see the documentation at Tool categories - Automatic E2E calculation |
|||
J1939 mode |
Mode: ‘Extended’ |
☐ |
bool |
Ignore the three most significant bits of the CAN-ID and J1939 source address. Extract signals from J1939-TP and ISOBus-ETP. |
|
Transmission confirmation |
☐ |
bool |
Activates acknowledged sending. Bus-Write test steps and Send tool jobs block until the message was successfully transferred on the bus or the confirm timeout expired. |
||
Timeout for transmission confirmation |
1000 |
int |
Period in miliseconds in which a message has to be sent successfully. Otherwise an error is created. (must not be larger than 64535ms). Is only used in active confirm mode. |
Jobs 🛈¶
ClearFrame¶
Erases the receiving buffer of given frame
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameId |
int |
Frame ID |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
result |
ByteStream |
ByteStream |
CloseIsoTpSession¶
Closes the ISO TP session.
Parameterization
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Return |
[False, True] |
bool |
Session successfully closed |
DeregisterFrameForInbox¶
Deregisters a frame that is streamed to the inbox
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameId |
int |
Frame ID |
|||
Inbox |
object |
Existing inbox |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
DeregisterStreamForInbox¶
Deregisters an ISO TP session.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
conId |
int |
Connection ID |
DisableSendFrameCyclic¶
Deactivate cyclic transmission of a message with given id
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameId |
int |
Frame ID |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
GetFirstValue¶
Returns the first value of the signal received since the test case started.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameName |
string |
Frame name |
|||
NodeName |
string |
Name of the electronic control unit |
|||
RawValue |
False |
[False, True] |
bool |
If ‘True’, the Raw value is returned. |
|
Reset |
False |
[False, True] |
bool |
If ‘True’ the first received value will be deleted after it has been read |
|
SignalName |
string |
Signal name |
GetLastReceptionTimestamp¶
Get the last reception timestamp in seconds
InitFrame¶
Registers the message ID for later use, e.g. ReadFrame
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameId |
int |
Frame ID |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
OpenIsoTpSession¶
Opens an ISO TP session.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
addressByte |
ByteStream |
Network target address or address extension (only relevant for extended or mixed addressing) - ByteStream of length 1 |
|||
addressMode |
0 |
int |
Code of addressing mode - Integer (0: Standard Addressing | 1: Extended Addressing) |
||
blockSize |
0 |
int |
Number (0 - 255) of consecutive frames that can be received without an intermediate flow control - Integer |
||
fillByte |
ByteStream |
Byte to fill messages (optional) - ByteStream of length 1 |
|||
flowControlAddressByte |
ByteStream |
Different network destination address or address extension for FlowControl (only relevant for extended and mixed addressing) - ByteStream of length 1 |
|||
flowControlId |
int |
Message ID for flow control messages (optional) - Hex (optional Integer) |
|||
isExtended |
-1 |
int |
Use Extended CAN-ID format? (1=yes / 29 Bits; 0=no / 11 Bits; -1 = Use setting from TBC) |
||
maxFrameLength |
0 |
int |
Maximum length of a frame in bytes (applies to both start, consecutive and last frames); if this value is set to 0, the maximum value described in ISO 10681-2 is used - Integer |
||
requestId |
int |
Message ID for ECU requests - Hex (optional Integer) |
|||
responseId |
int |
Message ID for ECU responses - Hex (optional Integer) |
|||
separationTime |
0 |
int |
Minimal time separation between successive fragments 0x00..0x7F => 0..127ms, 0x80..0xf0 => reserved, 0xf1..0xf9 => 100.900µs, 0xfa..0xff => reserved - Integer |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Return |
int |
Connection ID |
ReadFrame¶
Reads the given frame ID (use InitFrame before!)
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
doDelete |
False |
[False, True] |
bool |
Deletes the Frame after reading if “True” |
|
FrameId |
int |
Frame ID |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
result |
ByteStream |
ByteStream |
ReadFrameEx¶
Reads the given frame ID (use InitFrame before!)
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
doDelete |
False |
[False, True] |
bool |
Deletes the Frame after reading if “True” |
|
FrameId |
int |
Frame ID |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
result |
object |
CanFrame |
RegisterFrameForInbox¶
Registers a frame to be streamed to an inbox.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameId |
int |
Frame ID |
|||
Inbox |
object |
Existing inbox |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
|
saveAsCanFrame |
False |
[False, True] |
bool |
If True, the frame is saved as a CanFrame object, else as a ByteStream |
RegisterStreamForInbox¶
Registers an ISO TP session to be streamed into an Inbox.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
conId |
int |
Connection ID |
|||
inbox |
object |
Existing inbox |
ResetFirstValue¶
Erases the first received value of the given signal
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
FrameName |
string |
Frame name |
|||
NodeName |
string |
Name of the electronic control unit |
|||
SignalName |
string |
Signal name |
SendFrame¶
Sends message with given ID and data. Message ID must be registered in advance via the job “InitFrame”.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
DataByteStream |
ByteStream |
data to be send |
|||
FrameId |
int |
Frame ID |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
SendFrameCyclic¶
Cyclic transmission of a message with given ID and data. Message ID must be registered in advance via the job “InitFrame”.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Count |
int |
Number of sending repetitions |
|||
DataByteStream |
ByteStream |
data to be send |
|||
FrameId |
int |
Frame ID |
|||
Interval |
int |
Cycle time in ms |
|||
isExtended |
None |
[False, True] |
bool |
Address format: True for 29 bit, False for 11 bit, None uses the setting “Mode” from the test bench configuration |
SendStream¶
Send a data stream via ISO-TP.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
conId |
int |
Connection ID |
|||
data |
object |
Payload to be sent via ISO-TP |
|||
timeout |
int |
Timeout for sending the message in milliseconds |
SetFlowControlCTS¶
Activates to always send a Flow Control “ContinueToSend” message in response to a segmented request. Also new values can be assigned to the internal parameters BlockSize and SeparationTime.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
BlockSize |
int |
Number (0 - 255) of consecutive frames that can be received without an intermediate flow control - Integer If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept. |
|||
SeparationTime |
int |
Minimal time separation between successive fragments 0x00..0x7F => 0..127ms, 0x80..0xf0 => reserved, 0xf1..0xf9 => 100.900µs, 0xfa..0xff => reserved - Integer If None the most recent setting from the test configuration, the OpenDiagSession job or the previous SetFlowControlCTS call is kept. |
|||
SessionId |
object |
Handle of the diagnostic session. This can be either the name of the SUT specified in the TCF, the handle returned by the OpenDiagSession job or None (can only be used if there is one SUT specified). |
SetFlowControlWait¶
Activates to always send a Flow Control “Wait” messages in response to a segmented request. Note: While activated no segmented message can be received. Use the Job SetFlowControlCTS to reset this behaviour.
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
SessionId |
object |
Handle of the diagnostic session. This can be either the name of the SUT specified in the TCF, the handle returned by the OpenDiagSession job or None (can only be used if there is one SUT specified). |
|||
WaitTimeInterval |
0 |
int |
Wait time interval in ms. If set to 0, Flow Control “Wait” messages are only sent once, to respond to a segmented request. If set to a value greater than 0, Flow Control “Wait” messages will be sent periodically with the given interval in between. |
StartPlayback¶
Start playback of a recording
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
AscFile |
uri |
ASC file |
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
handle |
int |
A handle that can be used to stop the playback |
StopPlayback¶
Stop a running playback
Parameterization
Parameter
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
handle |
int |
A handle obtained from StartPlayback |