Port ELECTRICERRORSIM - DEFAULT¶
XIL-API-EESPort
Stimulation¶
This port has no stimulus capabilities.
Properties 🛈¶
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
Configuration file |
string |
Path to the configuration file of the EES port. Path has to be either absolute, or relative to the EES directory. If <auto>, the configuration file referenced by the TCF will be used. Otherwise this setting will take precedence over the path that is configured in the TCF. |
|||
Clear errors at end of test case |
☑ |
bool |
“True” enables automatic deletion of all electrical errors at the end of each test case and restoring the error-free state of the EES hardware. Select “False” to make electrical errors not deleted by the test case persist beyond the end of the test case. |
Jobs 🛈¶
GetActiveErrorCount¶
Returns the number of Error objects in the currently active ErrorSet. If no ErrorSet is active, -1 is returned.
Parameterization
Return value
Name |
Available if |
Default value |
Valid values |
Type |
Description |
|---|---|---|---|---|---|
return |
int |
ResetErrors¶
Clears all errors by appending an empty ErrorSet to the ErrorConfiguration and triggering that ErrorSet.